To Connect The User Interface - Daikin Altherma EHVH04S18CA3V Manuel D'installation

Basse température split
Masquer les pouces Voir aussi pour Altherma EHVH04S18CA3V:
Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

3 Installation
Connections to
Backup heater
backup heater power
(a)
type
supply
6 kW 3N~ 400 V
F1B
(*9W)
9 kW 3N~ 400 V
L1 L2 L3
L1 L1 L2 L2 L3 L3
(*9W)
(a) For configuration of the backup heater, see Quick wizard: Standard.
2
Fix the cable with cable ties to the cable tie mountings.
3
Configure the user interface for the respective power supply.
See Quick wizard: Standard.

3.5.5 To connect the user interface

1
Connect the user interface cable to the indoor unit.
2 1
X5M
X2M
A2P
A2P
a
b
a User interface delivered with the unit
b Optional user interface
2
Fix the cable with cable ties to the cable tie mountings.
Fixation of the user interface to the indoor unit
1
Insert a screwdriver into the slots underneath the user interface
and carefully separate the faceplate from the wallplate.
NOTICE
The PCB is mounted in the faceplate of the user interface. Be
careful NOT to damage it.
Installation manual
6
2
Connections to
terminals
X6M
X7M
1 2 3 4
5
6 7 8
3
4
From the rear
1x
b
5
Fixation of the user interface to the wall in case of installation as
room thermostat
1
2
3
From the rear
1x
b
Fix the wallplate of the user interface to the frontplate of the unit.
Cut off a 2 wire conductor.
Connect the wires to the user interface as shown below.
PCB
a
a Notch this part for the wiring to pass through with nippers
etc.
b Secure the wiring to the front part of the casing using the
wiring retainer and clamp.
Reinstall the faceplate onto the wallplate.
Insert a screwdriver into the slots underneath the user interface
and carefully separate the faceplate from the wallplate.
NOTICE
The PCB is mounted in the faceplate of the user interface. Be
careful NOT to damage it.
Fix the wallplate of the user interface to wall.
Connect the wires to the user interface as shown below.
PCB
a
EHVH/X04+08 + EHVH/X16
Daikin Altherma - Low Temperature Split
4P313772-1B – 2012.05

Publicité

Chapitres

Table des Matières
loading

Table des Matières