4 Configuration
Leaving water temperature: Modulation
#
Code
[A.3.1.1.5]
[8-05]
Leaving water temperature modulation:
Leaving water temperature: Emitter type
#
Code
[A.3.1.1.7]
[9-0B]
Reaction time of the system:
Depending on the system water volume
and the heat emitters type, the heat up
or cool down of a space can take
longer. This setting can compensate for
a slow or a quick heating/cooling
system by adjusting the unit capacity
during the heat up/cool down cycle.

4.2.6 Domestic hot water control

#
Code
[A.4.1]
[6-0D]
Domestic hot water set point choice:
[A.4.4.1]
N/A
How has the tank temperature to be
displayed on the user interface?
[A.4.8]
[6-0E]
The maximum temperature that users
can select for the domestic hot water.
You can use this setting to limit the
temperature at the hot water taps.

4.2.7 Contact/helpdesk number

#
Code
[6.3.2]
N/A
Number that users can call in case of
problems.
Installation manual
12
Description
0 (No): Disabled
1 (Yes): Enabled. The leaving
water temperature is calculated
according
to
the
difference
between desired and actual room
temperature.
This allows better matching of the
heat pump
capacity
to
actual
required capacity and results in
less
start/stop
cycles
of
heat pump and more economic
operation.
Description
0: Quick. Example: Small water
volume and fan coils.
1: Slow. Example: Large water
volume, floor heating loops.
Description
0
(Reheat
only):
Only
reheat
operation is allowed.
1 (Reheat + sched.): The domestic
hot water tank can only be heated
via a schedule.
2 (Scheduled only): Same as 1, but
between
the
scheduled
heatup
cycles, reheat operation is allowed.
As temperature.
As graphic: The temperature has to
displayed as available hot water for
x persons. If you choose this, you
also
have
to
configure
which
number equals which temperature
under [A.4.4.2]: Operation day.