POWER METER INSTALLATION
Installation
3.
Per national and local regulations only connect
your charger to a circuit with a branch circuit
overcurrent protection of 125% of the selected max
amperage setting of the device.
As per the chart below:
Position
2
3
4
5
6
7
For this limitation take only into account the wire and breaker
installed for the EV charger.
To ensure a safe installation, we recommend working
with a licensed installer or electrician. A professional
electrician can perform the necessary load calculations
to determine the maximum safe installation.
4.
Close the cover of the charger following the
instructions in the Installation Guide.
23
Circuit Breaker Rating
Amps
16A
20A
24A
32A
40A
48A
20A
25A
30A
40A
50A
60A