English
materials. With some porous and very low-reflecting materials, it is
possible that the full extent of the switching distance cannot be used.
Very strongly reflecting or mirroring materials can lead to deviations
in the switching distance. In order to save energy when using a bat-
tery-driven system and thus to increase battery life, distance calcula-
tions are clocked. The standard values of 3 seconds cycle time and the
resulting 1.5 seconds debounce time represent a good compromise
between response time and battery life.
Status signal
NOTICE
- If a jumper is inserted to set the status signal, this
jumper overwrites the receiver setting.
- If the receiver's status signal setting is to be used,
the jumper must be set as shown in Fig. »Delivery
state«.
The device can regularly transmit a status signal in which the current
switching state of the transmitter is transmitted, regardless of a
change in the switching state. The user can set the status signal at dif-
ferent intervals. There are two options for this:
®
1. sWave
configuration:
- See the receiver's mounting and wiring instructions.
2. Hardware jumper:
- Loosen the cover screws with a screwdriver. Remove the cover.
- After opening, a jumper becomes visible on the printed circuit board.
Now the desired time can be set. For the evaluation of the status sig-
nal, special receivers are available from steute.
- Put the cover on. Tighten the cover screws (0.45 Nm).
There must be no foreign bodies in the sealing area.
Delivery state:
receiver's status signal
Example position 1:
10 s status signal
4 / 20
Jumper
without jumper or 3 and 4
Position 1
Position 2
Position 3
Position 4
Battery
The remaining capacity of a battery is hard to evaluate, but an empty
battery can be assumed in case of doubt and with a battery voltage
<3.4 V at 20°C. In order to ensure reliable functioning, the battery must
be replaced. To do this, the 5 screws in the housing cover must be
opened using a torx-8 screwdriver. The battery should be inserted in
the direction shown by the symbols on the cover. Use only the desig-
nated battery type or a complementary battery type. Depending on the
country the device is supplied to, delivery will include an AA lithium
battery SL-760/3.6 V/2.2 Ah in a battery adapter, or a lithium battery
SL-2770/3.6 V/8.5 Ah without an adapter or a complementary
battery type.
Spare part:
Name
Lithium battery SL-2770/S 3.6 V/8.5 Ah
Lithium batteriy SL-760 (3.6 V/2.2 Ah AA)
Disposal
- Observe national, local and legal regulations concerning disposal.
- Recycle each material separately. Dispose of possibly contained
batteries correctly.
N.B.
Subject to technical modifications. Reconstruction and alterations to
the device are not allowed.
ESD
Ensure adequate ESD protection for all work that requires opening
the device.
Interval
no status signal
10 s
100 s
1,000 s
10,000 s
Article no.
1202806
1351045
Table des Matières
loading

Ce manuel est également adapté pour:

Rf 96 sds sw915Rf 96 sds sw917Rf 96 sds sw922

Table des Matières