Performance Data 2-Pipe (Type BN/BC/FN/FC)
Fan
Model
Flow
Speed*
(l/h)
Normal
341
2- 080
Medium
341
Boost
341
Normal
450
2- 100
Medium
450
Boost
450
Normal
600
Medium
600
2- 120
Boost
600
Normal
700
Medium
700
2- 140
Boost
700
Normal
800
Medium
800
2- 160
Boost
800
For BTUs multiply Watts by 3.412.
Performance Data 4-Pipe (Type BN/BC/FN/FC)
Fan
Model
Flow
Speed*
(l/h)
Normal
300
4- 080
Medium
300
Boost
300
Normal
350
1- 100
Medium
350
Boost
350
Normal
400
Medium
400
4- 120
Boost
400
Normal
450
Medium
450
4- 140
Boost
450
Normal
500
Medium
500
4- 160
Boost
500
For BTUs multiply Watts by 3.412.
*Outputs shown at fan speeds via controls unit - may differ with external controller.
Heat Output (Watts)
ΔT20
ΔT25
ΔT30
738
940
1146
989
1260
1537
1360
1733
2113
1012
1289
1572
1352
1723
2101
1892
2412
2941
1214
1548
1887
1643
2094
2553
2409
3070
3743
1428
1820
2219
1945
2478
3022
2916
3716
4531
1647
2099
2560
2246
2863
3491
3422
4362
5318
Heat Output (Watts)
ΔT20
ΔT25
ΔT30
517
658
802
692
882
1076
952
1213
1479
708
902
1100
946
1206
1471
1324
1688
2059
850
1084
1321
1150
1466
1787
1686
2149
2620
1000
1274
1553
1362
1735
2115
2041
2601
3172
1153
1469
1792
1572
2004
2444
2395
3053
3723
ΔT35
ΔT40
ΔT45
1355
1567
1781
1817
2101
2388
2499
2889
3284
1859
2149
2443
2484
2872
3265
3477
4020
4569
2231
2580
2932
3018
3490
3967
4425
5117
5815
2624
3034
3449
3573
4131
4695
5357
6194
7040
3027
3499
3977
4127
4772
5424
6288
7270
8263
ΔT35
ΔT40
ΔT45
949
1097
1247
1272
1471
1672
1749
2022
2299
1301
1504
1710
1739
2010
2286
2334
2814
3198
1562
1806
2052
2113
2443
2777
3098
3582
4071
1837
2124
2414
2501
2892
3287
3750
4336
4928
2119
2449
2784
2889
3340
3797
4402
5089
5784
Cooling (Watts)
Condition 7-12-27
ΔT50
Total
Sensible
1997
707
2678
1126
3682
1648
2739
1011
3661
1600
5124
2304
3288
1520
4448
1960
6521
2918
3867
1490
5265
2320
7894
3533
4460
1729
6082
2679
9266
4147
Relative Humidity: Sensible cooling at 50%.
Cooling (Watts)
Condition 7-12-27
ΔT50
Flow (l/h)
Total
1398
350
672
1875
350
1070
2577
350
1566
1917
450
960
2563
450
1520
3587
450
2189
2302
600
1444
3114
600
1862
4565
600
2772
2707
700
1416
3686
700
2204
5526
700
3356
3122
800
1643
4257
800
2545
6486
800
3940
Relative Humidity: Sensible cooling at 50%.
527
829
1227
753
1178
1716
931
1442
2173
1110
1707
2631
1288
1972
3088
501
788
1166
715
1119
1630
884
1370
2064
1055
1622
2499
1224
1873
2934