GB
US
17. Correction of Malfunctions
Malfunction
No spray tanning
lotion comes out of
the nozzle
Spray tanning
lotion drips out of
the nozzle
Atomization too
coarse
Uneven spray
pattern
Excessive overspray
Spray tanning
lotion runs down
body
The tan is patchy or
blotchy
12
All manuals and user guides at all-guides.com
Cause
•
Nozzle clogged
•
Material volume setting
turned too far to the left (-)
•
No pressure build-up in
container
•
Container empty
•
Feed tube loose
•
Feed tube clogged
•
Spray tanning lotion has
accumulated on the air cap,
nozzle or needle
•
Nozzle loose
•
Nozzle seal worn
•
Nozzle worn
•
Material volume adjusting
screw turned too far to the
right (+)
•
Nozzle contaminated
•
Too little pressure build-up in
container
•
Air filter heavily soiled
•
Spray tanning lotion in the
container is running out
•
Nozzle seal worn
•
Air filter heavily soiled
•
Distance too large
•
Material volume adjusting
screw turned too far to the
right (+)
•
Too much spray tanning
lotion applied
•
Spray paths overlap too much
•
Spraying distance too small or
spray movement too slow
•
Skin was not correctly
prepared
•
Spray movement not even
enough
Spray Tanning System
Aura Allure Spray Tan
Aura Allure Spray Tan
Remedy
•
Clean
•
Turn material volume
adjusting screw to the right
(+)
•
Tighten container
•
Refill
•
Insert
•
Clean
•
Clean
•
Union nut tighten
•
Change
•
Change
•
Turn material volume
adjusting screw to the left
(-)
•
Clean
•
Tighten container
•
Replace
•
Refill
•
Replace
•
Replace
•
Reduce distance
•
Turn material volume
adjusting screw to the left
(-)
•
Carefully dab affected
points with a towel, reduce
flow setting if required and
lightly overspray again
•
Correct by lightly
overspraying