Télécharger Imprimer la page

WEBTEC VFD120MD Série Mode D'emploi page 5

Publicité

Les langues disponibles

Les langues disponibles

Specifications
Maximum pressure:
Input and Regulated flow capacity: Input up to 120 lpm (32 US gpm) and regulated from 0.5 lpm (0.132 US gpm) up
Material:
Weight:
This equipment is intended for use within industrial and residential environments and does not suffer any degradation
in performance when subjected to test conditions according to EMC directive BS EN 61326-1:2013 emission (group 1,
class B) and interference immunity (industrial environment).
Valve Assembly Fitting
The installation of this valve and associated control components should only be undertaken by suitably qualified
personnel.
Securely mount the valve in position with the bolt holes provided in the body.
Make all hydraulic connections to the valve with flexible hose at least 100mm long. Hoses should be clamped to
avoid lateral forces on the ports.
Check IP (Ingres Protection) rating before installing in wet areas. Use a M12 cap to protect connector when no cable
is present. IP rating only applies if unit is fully connected.
Use the information stated on 'Electrical Connection Detail' section as a guide to connect the M12 cable to the Power
Supply and the Control Signal.
Connect M12 right angle female connector to the M12 connector fitted on the valve.
420 bar (6000 psi)
to 110 lpm (30.0 US gpm aprox) dependent on model
Steel components in a cast Ductile iron body. Drive mechanism mounted on
aluminium supports
2.75 kg
3

Publicité

loading

Produits Connexes pour WEBTEC VFD120MD Série

Ce manuel est également adapté pour:

Vfd120md-120-j-p