SET DETECTION RANGE (IF REQUIRED)
1. Once the device is paired, you may edit the
settings by navigating to Device Management
screen and finding the DEVICE CARD (1). You
must be in Bluetooth range to the device.
2. Press on the DEVICE CARD (1) and scroll down
to find the CONNECT (2) button.
3. Once the app connects to the device, a
"Settings" button will be available.
4. Enter the Settings screen and adjust IR
sensor distance as needed and press "Apply"
5. Actuate the flush valve. Cover sensor with a
piece or cardboard or similar item for 10 seconds.
Unit will flush for approximately 3 seconds..
Flush durations should not be modified unless
specified in the by manufacturer.
1" - 2" (30mm - 50mm
1
1
BLINKING LED
DETECTION ZONE
400mm TO 800mm
(Factory Setting: 400mm)
1
BLINKING LED
2