Manufacturer
Name
Part_Number
Revision
Serial_Number
Chassis
Manufacturer
Name
Part_Number
Serial_Number
Description : A power supply has failed to maintain a good POK (Power On
OK) condition.
Response
: The system will shutdown in a non-graceful fashion.
Impact
: The platform will restart with the affected component
deconfigured.
Action
: Please refer to the associated reference document at
http://support.oracle.com/msg/SPT-8001-XC for the latest
service procedures and policies regarding this diagnosis.
faultmgmtsp>
Certaines alimentations disparaîtront de la liste des alimentations pour cet hôte dans Oracle
ILOM. Ce point est illustré dans l'exemple ci-dessous.
->
show
/Servers/PDomains/PDomain_0/System/Power/Power_Supplies
/Servers/PDomains/PDomain_0/System/Power/Power_Supplies
Targets:
Power_Supply_6
Power_Supply_7
Power_Supply_8
Power_Supply_9
Power_Supply_10
Power_Supply_11
Power_Supply_12
Power_Supply_13
Power_Supply_14
Power_Supply_15
...
->
: Oracle Corporation
: CMIOU Module
: 7090838
: 04
: 465769T+14456C01VH
: Oracle Corporation
: SPARC M7-16
: 32397701+7+1
: AK00192372
Problèmes recensés
Informations de dernière minute
47