Error
Code
Er0
Er1
Er2
Er3
Symbol
Er4
Er5
Er9
Warning: To reduce the risk of injury, the user must read the
instructions manual carefully.
This symbol, placed before a safety comment , indicates a
kind of precaution, warning, or danger. Ignoring this warning
may lead to an accident . To reduce the risk of injury, fire, or
electrocution, please always follow the recommendation
shown below.
Problems
Temperature sensor
cutting out
Battery protection
cutting out
Fan overload cutting
out
Motor start error(the
rotor is
blocked or the
differential pressure in
refrigeration system is
too high
compressor speed
error protection .
Thermal cut-out
(Overload or internal
temp too high)
Temperature sensor
disconnection
Solution Method
Change the temperature
sensor line
1.Change/charge the battery
2. Lower battery protection
switch to lower setting
clean fan or change the fan
Disconnect power for30
minutes then
re-start
Reduce load on refrigeration
system increase temperature
setting.change the main
controller
Move refrigerator to a well
ventilated place, allow
compressor to cool. then re-
start . Ensure all vents and
internals are clean. Clean
with compressor air
1.Tighten the temperature
sensor line
2.Change the temperature
sensor line
- 2 -