INSTALLATION INSTRUCTIONS
Mode
Buffer
Battery
Parameter
Input Voltage
Input current
Output Voltage
Output Voltage
Efficiency
Overvoltage category
Pollution Degree
Altitude During Operation
BATT (Battery) Charging Current
Nominal Battery Voltage (EOC)
Battery Resistance Test
Battery Test Current Pulse
BATT Test Frequency [mins]
Batt (Battery) Test button
Battery Warning Voltage
Battery Disconnection Voltage
External Battery Fuse
Automatic Battery 'end of charge'
Voltage/Temp Compensation Range
DC-OUT OK Open Collector
Signal Relay(s) Contact Ratings
Operating Ambient Temperature
Storage Ambient Temperature
Input and Output Connection Wire
Size and Torque
Weight
For more detailed information visit website
5 6
7
8
9
http://www.tracopower.com
I
Nominal @ 24V
out
10A
10A
Condition
Buffer Mode
Buffer Mode
Buffer Mode
Battery Mode
Battery Mode
OVC II
PD 2
2000m max.
Buffer Mode
25°C Ambient
Buffer Mode at 25°C Amb.
Buffer Mode at 25°C Amb.
Buffer Mode
Buffer Mode
Battery Mode
Battery Mode
Buffer/Battery Mode
Battery Mode
Buffer/Battery Mode
Buffer/Battery Mode
Buffer/Battery Mode
-
1.5 – 4 [mm2]/16-10 [AWG]
at 0.7 [Nm]
530g
www.tracopower.com/products/TIB240-124BCMU.pdf
TIB 240-124BCMU
Output Current
I
Max
out
12A
End user must provide current limitation
12A
Nominal 24V (Range 24-28.5V) Fully stabilized
12A Max continuous current, 20A Max peak current (4s max)
Max 2500V peak transient
Select switch HI/LO 2.4A/1.2A (typ) at 24V VBATT Fig.1.
Select switch HI/LO 10mins/1min (typ) Fig.1.
Push to perform a battery test Fig.1.
15A F (Fast fuse) Blade Type (Littelfuse 0287015 ATOF) Fig.1.
0°C...+60°C (with external temperature sensor) Fig.2.
Factory setting 'EOC' 27.2V with no sensor
60V/0.4A max internal limitation Fig.2.
30VDC 1A / 125VAC 1A Fig.2.
Signal Connection Wire Size
and Torque
Max. Dimensions (from DIN rail)
Height x Width x Depth
Battery Controller
Comment
Constant current limitation
Settings
V
(0.5V max)
in-
24V (typ)
96% (typ)
27.2V
100 mΩ (max)
2A for 100ms (typ)
22V (typ)
20V (typ)
0°C...+60°C
-25°C...+70°C
0.1– 2 [mm2]/28-14 [AWG] at
0.2 [Nm]
125mm x 49mm x 120mm
Rev: 1.3 / Jan 06,2025

Publicité

loading

Sommaire des Matières pour TRACO POWER TIB 240-124BCMU

  • Page 1 INSTALLATION INSTRUCTIONS TIB 240-124BCMU Battery Controller Output Current Mode Nominal @ 24V Comment Buffer End user must provide current limitation Battery Constant current limitation Parameter Condition Settings Input Voltage Buffer Mode Nominal 24V (Range 24-28.5V) Fully stabilized Input current Buffer Mode...
  • Page 2 Installation Instructions:  External power supplies must be fully stabilised (SELV) and should be of the same voltage ratings.  Do not cover any ventilation holes. Leave a free space of minimum 50mm (2in.) above and below the device.  The correct mounting position for optimal cooling performance must be vertical as per Fig.1.