INSTALLATION:
Before installing this product, make sure it complies with your request and that it suits your application!
1. Unpack the timer and visually inspect for any transport damage incurred after leaving our factory.
2. Depressurise the system and shut off the power supply before installation or maintenance is carried out!
3. Take the gasket and place it over the coil connection pins.
- Make sure there is no debris between the gasket and the coil!
4. Mount the timer on to the coil as illustrated, you can mount the timer up-right or upside-down.
5. Connect your power supply as illustrated. CAUTION! Always connect protective conductor and check
electrical continuity.
6. Place the connector gasket on the connector, place the connector on the timer as illustrated and
tighten the screw (max. torque 1Nm).
- Make sure both gaskets are secured properly to ensure IP65 rating.
7. After double checking that the power supply corresponds with the voltage specified on the coil
and falls within the range specified on the back of the timer, you can switch the power supply ON.
8. Slowly restore normal system pressure.
- Press the TEST button to check the valve function.
9. You can adjust the ON and OFF cycle times to suit your system.
- Your timer is now ready for operation!