Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

EN
English

MACHINE SETUP

1.
Before each use, inspect the machine, hoses, and hard surface
tool for cleanliness and completeness. Ensure the spray tips
2.
Close and tighten the recovery tank cover and screw the cap
onto the drain hose.
3.
Fill the solution tank with 15 gallons/57 liters of clean water
(maximum temperature 120°F/49°C) using a garden hose or
bucket. If choosing to use the AUTO-FILL and AUTO DUMP
feature skip to steps 4-7.
NOTE: For optimum cleaning performance, it is recommended
detergent using a pump-up sprayer instead of adding detergent
in machine. If you choose to use cleaning detergent in machine
follow proper mixing and handling instructions on detergent
after each use to prevent detergent buildup. The use of
powdered detergents with machine is discouraged.
6
4.
Auto Fill - Connect the hose adaptor supplied with the
machine to the Auto Fill Hose Connection at front of
machine. Then connect a water supply garden hose to the
hose adapter.
Auto-Fill Hose
Connection
Hose Adaptor
5.
Turn on the water supply hose. The Auto-Fill valve located
when tank reaches capacity. When the water level drops,
the tank again.
6.
Auto Dump - Attach a garden hose to the Auto Dump Hose
Connection and route the garden hose to dump site.
NOTE: When using the Auto-Dump feature use a 3/4" garden
hose. The maximum garden hose length is 75 ft/23 m with a
gradual vertical rise no more than 15 ft/4.5 m from machine to
dump site.
Auto Dump Hose
Connection
7.
Turn the Auto Dump switch on when ready to begin
cleaning. The Auto-Dump pump will automatically turn
on when the recovery tank reaches full capacity and begin
discharging the recovered water.
Auto Dump
Switch
Nobles Quick Clean 12 (01/2014)

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

1072857 - 120v

Table des Matières