Télécharger Imprimer la page

Textron Greenlee Utility H4670 Manuel D'instructions page 8

Publicité

Les langues disponibles

Les langues disponibles

Operation
Keep away from the pump outlet/discharge hose
during operation. Liquid and debris will be thrown by
the pump.
Failure to observe this warning could result in severe
injury or death.
Do not change accessories, inspect, adjust, or
clean tool when it is connected to a power source.
Accidental startup can result in serious injury.
Wear eye protection when operating
or servicing this tool.
Failure to wear eye protection could
result in serious eye injury from
flying debris or hydraulic oil.
Skin injection hazard:
• Do not use hands to check for
leaks.
• Do not hold hose or couplers
while the hydraulic system is
pressurized.
• Depressurize the hydraulic system
before servicing.
Oil under pressure easily punc-
tures skin, causing serious injury,
gangrene, or death. If you are
injured by escaping oil, seek medical
attention immediately.
Greenlee / A Textron Company
All manuals and user guides at all-guides.com
H4670 Submersible Trash Pump
1. Connect the discharge hose to the discharge port.
2. Start the hydraulic power source.
Do not use the hydraulic hoses to lower or lift the
pump. This will weaken or damage the hoses or
fittings, and could cause a hydraulic fluid leak.
Failure to observe this precaution may result in
property damage.
3. Attach a rope or other device to the handle of the
4. Actuate the control valve of the power source to
5. When finished pumping, actuate the control valve to
Maintenance
Use this maintenance schedule to maximize the tool's
service life.
Note: Keep all decals clean and legible, and replace
when necessary.
Daily
1. Wipe all tool surfaces clean.
2. Inspect the hydraulic hoses and fittings for signs
3. Install dust caps over the hydraulic ports when the
Monthly
1. Perform a thorough inspection of the hydrau-
2. Remove and clean the base legs and base plate.
8
Note: Allow the power source to run for a few
minutes to warm the hydraulic fluid.
pump. Lower the pump into the material to be
pumped.
start the flow of hydraulic fluid.
stop the flow of hydraulic fluid.
of leaks, cracks, wear, or damage. Replace if
necessary.
tool is disconnected.
lic hoses and fittings as described in publication
99930323, SAE J1273 (Hose and Hose Assemblies).
Remove any material that may have accumulated
near the inlet port.
4455 Boeing Dr. • Rockford, IL 61109-2988 USA • 815-397-7070