Wiring diagrams for connecting the unit to different kinds of pump's motors
Wiring diagram for
connection of single-
phase 220V pumps up
to 1,1 Kw.
Possible working defects
Type of defect
Causes depending on the unit
The pump does
The electronic card is broken
not start
The pump does
- The electronic card is broken.
not stop
- The flow detector is blocked in the
upper position.
- The reset button is blocked.
- The pump does not provide sufficient
pressure.
Intermittent
- The electronic card is broken.
pump working
- The pump does not provide sufficient
pressure.
The pump is
- The electronic card is broken.
jammed
- The pump provides a pressure which is
lower than the restarting pressure
Technical data
Input voltage
Frequency
Intensity max.
Protection rating
Maximum working pressure
Max working temperature
Connection
Nota:
i
The product must be used for the pumps which the power is least 800 W or more. Please
don't use it if the power is less than 800 W.
Wiring diagram for connection of
single phase 220V pumps over 1,1
Kw. Through remote control switch.
SPECIFICATIONS FOR REMOTE
CONTROL SWITCH Minimum
contacts capacity of 4 Kw or 5.5 HP
approx., 220 V.
VCP-TRONIC
220-240 V
50-60 Hz
Wiring diagram for connection of
three phase 380V motor pumps
through remote control switch
through remote control switch
SPECIFICATIONS FOR REMOTE
CONTROL SWITCH Minimum
contacts capacity of 4 Kw or 5.5 HP
approx, 220 V.
Causes not depending on the unit
- Voltage failure.
- Pump jammed sufficient.
- Electric cables inverted (Line/motor).
- Presence of leaks which are higher than
the minimum flow 0,61 l/min.
- Presence of leaks which are lower than
the minimum flow 0,61 l/min.
- Water failure.
- Suction problems.
10A
IPX4
10 bar
60ºC
1" M
GB
9