Erp Data; Operating Limits Heat Pump - Ferroli OMNIA S 3.2 Manuel D'installation, D'utilisation Et D'entretien

Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

OMNIA S 3.2
Indoor unit technical data
Power supply
Heat exchanger type
Pump type
System expansion tank volume
System safety water valve set
System water connections
DHW water connections
Hydraulic fittings / liquid line ***
Hydraulic fittings / gas line
Minimum plant water content
DHW boiler - minimum surface of the coil
(minimum / recommended)
System electric heater
SWL - Sound power level
Max current input
Net weight
Operation weight ****
Packed unit weight
*** For matching with external units mod. 4-6 a reduction fitting from 3/8 "SAE to 1/4" SAE is provided for liquid line Ø 6.35.
**** Weight refers to basic unit without accessories

3.2 ERP data

Models
low temperature (water outlet at 35°C)
Seasonal space
heating energy
efficiency class
medium temperature (water at 55°C)
low temperature (water outlet at 35°C)
SCOP
medium temperature (water at 55°C)
water at 7°C
SEER
water at 18°C
NOTA: Declared according to European regulation 811/2013. The values are referred to units without options and accessories.

3.3 Operating limits heat pump

COOLING MODE
Leaving water temperature °C
Operation range by heat pump with
possible limitation and protection.
10
220/240-1-50
Electronic circulator (8 mca)
15
steel
1,4 / 2,5
enamel
1,7 / 3,0
42
42
42
33
35
35
4
6
191
195
205
129
138
131
4,85
4,95
5,21
3,31
3,52
3,36
4,99
5,34
5,83
7,77
8,21
8,95
HEATING MODE
-
-
-
Leaving water temperature °C
Operation range by heat pump with possible limita-
tion and protection.
With IBH (system electric heater) installed.
Maximum inlet water temperature line for heat
pump operation.
Cod. 3541V941 - Rev. 00 - 09/2021
16
Stainless steel brazed plates
Electronic circulator (9 mca)
10
3
1" GAS F
3/4" GAS F
3/8" SAE / Ø 9,52
5/8" SAE / Ø 15,88
1,75 / 4,0
2,5 / 5,6
3
42
43
43
43
14
35
37
37
8
10
12
14
204
189
185
A+++
136
135
135
A++
5,19
4,81
4,72
3,49
3,45
3,47
5,98
4,89
4,86
8,78
7,10
6,90
NOTE FOR DHW MODE: leaving water temperature is the tem-
perature of the water produced by the unit and not the DHW tem-
perature available to the user; the DHW temperature is in fact a
function of this parameter and of the coil surface of the DHW boiler.
16T
380/415-3-50
V-ph-Hz
25
6
dB(A)
43
43
43
10
36
38
38
16
12T
14T
16T
182
189
185
182
133
135
135
133
4,62
4,81
4,72
4,62
3,41
3,45
3,47
3,41
4,69
4,86
4,83
4,67
6,75
7,04
6,85
6,71
DHW MODE
-
-
-
Leaving water temperature °C
Operation range by heat pump with possible limita-
tion and protection.
With IBH (system electric heater) installed.
Maximum inlet water temperature line for heat
pump operation.
EN
UM
-
-
l
bar
-
-
-
-
l
m
2
m
2
kW
A
kg
kg
kg
UM
ηs (%)
class
ηs (%)
class
W/W
W/W
W/W
W/W
85