General
For all actions in machinery or electric parts: ensure the plug is
disconnected from the mains.
It is possible that sharp parts appear in the engine room. Be careful
if you have to do operations in the engine room. It is possible that
parts in the engine room are very hot (90ºC).
Convince yourself that all parts are chilled enough before you do
operations in the engine room. Always mount eventual removed
grids and/or other parts on the same place as before.

Filling the cabinet

When filling the cabinet please ensure that the cans inside do not
obstruct the air inlets or fan outlets, as this will reduce the circulation of
the cold air.
• Re-fill the cabinet in the evening to allow maximum cooling time
before serving.
• Ensure that stock is rotated efficiently.
• To ensure maximum cooling time replenish stocks regularly rather
than once a day.

Fault finding

Please ensure the plug is disconnected from the mains:
Symptom: Temperature is too high with correctly set thermostat.
Cause:
a. The refrigeration machine has no power supply.
b. The cooler is overfull.
c. The door is not closed fully.
d. The air flow threnches are covered.
e. The evaporator is frozen.
f. The thermostat is out of order.
g. The compressor is out of order.
Solution:
a. Check/repair power supply.
b. Replenish capacity more regularly.