GENERAL SETUP & OPERATION, ELECTRIC MODEL SVF-10E
1.)
Place fan in a clean air environment.
Note: Air quality of the confined space should be tested prior to ventilation. If air quality
of the confined space is unacceptable, consult a trained professional. If hazardous or
explosive gases or dusts are present, use fan Model SVF-10EXP.
2.)
Inspect fan for damaged or worn parts. Inspect all ducting and couplings for air leaks prior
to fan operation.
3.)
Install duct cuff to inlet and/or exhaust flange(s) and tighten cinch strap. Keep bends
and kinks in ducting to a minimum to maximize air flow.
Note: The SVF series fans are supplied with two 10" to 8" adapters. They can be used
to attach 8" or 10" duct to the air discharge or inlet side of the blower. If the blower is to
be used in series, the intake adapter should be used. Multiple fans can be used in series to
achieve ventilation with long lengths of ducting. Do not use more than 50ft. of duct on the
inlet or discharge side of the fan as severe air flow loss will result. If the fan is used as a
single unit, greater discharge flow will be achieved by removing the intake duct adapter.
4.)
Connect fan to power source.
Note: The standard electric model, SVF-10E, is equipped with a standard 3 prong plug
and can be plugged into a standard 120VAC/15amp/60Hz receptacle. If an extension
cord is to be used, the minimum recommended size is 14 AWG up to 25'. For longer
cords, refer to the National Electric Code tables, Article 400.
5.)
Push on/off switch located on the right side of the conduit box to the "on" position. The
unit is know operational.
Note: DO NOT use this fan to pull paint vapors through the air intake as this will
void all warranties.
MAINTENANCE
Keep blower motor dry and free from contaminants and dust.
Check periodically to ensure moving parts are free from obstructions.