STAR 10.2 C- STAR 12.2 C
Rev.1 03/08/2017
Use and maintenance manual
Page 44
EN
Protection from rain
T fitting for condensation
Fig.6
This type of installation (See Fig.6) requires a horizontal section to connect to a pre-existing chimney pot.
Respect the slope indicated in figure, in order to reduce the ashes depositing in the horizontal tube. In the lower part of the chimney
pot, there is a "T" type fitting installed with inspection cap, in the same was as the chimney pot opening.
It is prohibited to install a 90° bend for the initial segment, since the ashes would quickly obstruct smoke passage, causing draught
problems in the stove. (See Fig.2)
IT IS MANDATORY TO USE STAINLESS STEEL AIR-TIGHT TUBING WITH SILICONE OR VITON
GASKETS.
®
Hot air ducting
The stove is equipped with a rear outlet (model 10.2 C) or two rear outputs (model 12.2 C) of 80 mm (outside diameter) to allow the ducting
of hot air flows to other rooms.
To create the ducting system:
- use pipes with internal diam. of 80 mm able to resist temperatures of at least 150°C;
- use pipes that are smooth inside, insulated or isolated;
- reduce, as far as possible, the ducting path and the single pipe section must not be longer than 6 m;
- avoid constrictions or section reductions, tight bends and downsloping sections.