Olsen C Série Manuel D'installation, D'emploi Et D'entretien page 18

Table des Matières

Publicité

Table A-9 Direct Drive Blower Characteristics - 1/2 HP ECM Variable Speed Constant CFM Motor
Modèle de fournaise
HMLV 60-100
SW1 POSITION DE
L'INTERRUPTEUR DIP
THERMIQUE
A (1=OFF, 2=OFF)
B (1=SUR, 2=OFF)
C (1=OFF, 2= SUR)
D (1=SUR, 2= SUR)
SW2 POSITION DU
COMMUTATEUR DIP
COOL
A (1=OFF, 2=OFF)
B (1=SUR, 2=OFF)
C (1=OFF, 2= SUR)
D (1=SUR, 2= SUR)
SW3 POSITION DU
COMMUTATEUR DIP
COOL
A (1=OFF, 2=OFF)
B (1=SUR, 2=OFF)
C (1=OFF, 2= SUR)
D (1=SUR, 2=O SUR)
SW4 POSITION DU
COMMUTATEUR DIP
DELAY
A (1=OFF, 2=OFF)
B (1=SUR, 2=OFF)
C (1=OFF, 2= SUR)
D (1=SUR, 2= SUR)
PROFIL DE RETARD POUR LE REFROIDISSEMENT OU LE CHAUFFAGE DE LA POMPE À CHALEUR
AUCUN AJUSTEMENT
OBLIGATOIRE
N/A
ANNEXE A - VÉRIFICATION ET RÉGLAGES
Souffleur
Moteur HP
100-10T DD
1/2 HP ECM
ENTRÉE
CFM AVEC COMMUTATEUR
[USGPH]
DIP SW3-ADJ POSITION A
0.65
1100
0.85
1452
0.75
1223
0.50
823
VENTILATEUR CONTINU
TAILLE D'AC
CFM AVEC COMMUTATEUR
[TONNES]
DIP SW3-ADJ POSITION A
3
600
2.5
500
2
400
1.5
300
CHAUFFAGE DE POMPE DE REFROIDISSEMENT OU DE CHALEUR
TAILLE D'AC
CFM AVEC COMMUTATEUR
[TONNES]
DIP SW3-ADJ POSITION A
3
1200
2.5
1000
2
800
1.5
600
PROFIL DE RETARD POUR LE CHAUFFAGE DE L'HUILE
DÉLAI DE PRÉEXÉCUTION
NTRÉE
SUR
[USGPH]
NIVEAU DE TEMPS-CFM
0.65
90 SECONDS - 0%
0.85
75 SECONDS - 0%
0.75
75 SECONDS - 0%
0.50
120 SECONDS - 0%
TAILLE D'AC
PRE-RUN SUR DELAY
[TONNES]
TIME - CFM LEVEL
TOUS
7.5 MINUTES - 82%
Moteur FLA
CHAUFFAGE À L'HUILE
CFM AVEC COMMUTATEUR
DIP SW3-ADJ POSITION B
CFM AVEC COMMUTATEUR
DIP SW3-ADJ POSITION B
CFM AVEC COMMUTATEUR
DIP SW3-ADJ POSITION B
COURT TERME SUR
RETARD
NIVEAU DE TEMPS-CFM
90 SECONDS - 50%
75 SECONDS - 63%
90 SECONDS - 50%
120 SECONDS - 50 %
COURT TERME SUR
RETARD
NIVEAU DE TEMPS-CFM
AUCUN
18
7.7
CFM AVEC COMMUTATEUR DIP
SW3-ADJ POSITION C
1265
1500
1406
946
CFM AVEC COMMUTATEUR DIP
SW3-ADJ POSITION C
690
575
460
345
CFM AVEC COMMUTATEUR DIP
SW3-ADJ POSITION CC
1380
1150
920
690
RETARD D'ARRÊT
NIVEAU DE TEMPS-CFM
5 MINUTES - 63%
5 MINUTES - 63%
5 MINUTES - 63%
5 MINUTES - 63%
RETARD D'ARRÊT
NIVEAU DE TEMPS-CFM
PN 30173F, Rev. G [01/02/2019]
∆T
45-75°F
935
1234
1040
700
510
425
340
255
1020
850
680
510
AUCUN