TOUCHCONTROL Panel
Basic control functions:
-
Power Boost Function (10min at 100% power) / button per hotplate.
-
"Bridge" function
-
Safety lock function.
-
Timer: timer per cooking zone.
-
Pan detection.
-
Residual heat indication for each zone (H).
-
Protection against accidental key activation.
-
H-CONNECT PANEL
Switching the hotplate on/off
Place the pot in the centre of the cooking zone. Make sure the cooking zones are clean and dry.
The plate is turned on by touching the ON/OFF key
beep sounds and all the displays on the plate light up.
If the selection of a cooking zone on the hob is not made within 10 seconds, the hob will
automatically switch off.
The hob is switched off by touching the ON/OFF button for 1 sec. A beep sounds and all cooking
zones are switched off. The purpose of these beeps is to distinguish the OFF action from all
others.
The ON/OFF key will be locked to turn on the hob if:
-
the keys lock is activated
-
if there is an error in the appliance.
Managing the hob
The hob is equipped with cooking zones of different diameters and power outputs. The area to
be heated is clearly marked on the hotplate. For best hotplate performance, place cookware
exactly in the designated cooking zone.
Selecting a cooking zone
A cooking zone is selected by touching the zone selection key
display shows the power level.
The selected cooking zone display shows the power level with "more brightness", so as to make
it stand out from the other cooking zones not selected.
The selection of the cooking zone will be terminated if:
-
5 seconds elapse without giving any command.
-
If another cooking zone is selected.
When the cooking zone selection is complete after 5 seconds, a beep sounds and all the displays
on the hob show the power levels again with the same brightness.
for 1 second, when it is unlocked. A
, a beep sounds and zone
11