7. Possible Malfunctions

In case of anomalies use the table below before calling the service company or informing
the vendor.
Problem
No cooling
Insufficient
cooling
efficiency
Loud operation
The compressor
does not start
automatically
- 34 -
Cause
• The plug is not connected to
the socket
• Damaged fuse
• Power supply failure
• Damaged temperature
controller
• Direct sunlight or heat
sources in the vicinity of the
device
• Poor air circulation around
the device
• The door is not closed
completely or opened
too long
• Too little distances between
the stored food or too much
food in the device
• Covered air inlet or outlet
• The device is not placed on
the even surface
• The refrigerator touches
walls or other objects
• Overloaded refrigerated
showcace
• The door was opened
too long
Solution
• Connect the plug correctly
• Check power supply
• Check power supply
• Contact the vendor.
• Move the device away from
the heat sources
• Assure sufficient distances
to the walls or other objects
• Close the slide doors,
minimize the opening time
• Assure sufficient spaces
between the food products,
remove the food excess
• Do not cover the air inlet
and outlet holes
• Place the refrigerator on the
even surface
• Ensure sufficient distance
between the device and
walls or other objects
• Remove excess of food
• Minimize the door opening
time