Table Des Matières - Dostmann Electronic P790 Mode D'emploi

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

Summary
1. Handling
1.1. General advices
1.2. Setting to work
1.3. Switch on/off
1.4.1. Measuring unit switching (Unit)
1.4.2 Automatische Fühlererkennung (Smartprobes)
1.4.3 Probe selection / (Prob)
1.4.4 Difference temperature (L in2)
1.5. Recalling memory data (HOLD/MAX/MIN/AVG)
2. Power supply / Changing the battery
3. Error codes / troubleshooting
...............................................................................................................................
1. Handling
1.1 General advices
- For cleaning the instrument please do not use abrasive cleaner but a dry or
wet piece of cloth.
- Please store the measuring instrument in a dry and clean place.
- Avoid any force like shocks or pressure to the instrument.
- Do not use force to connect the probe or interface plugs in. The interface
plug is different from the probe plug.
- lf no sensor is connected to the instrument while switching on „open"
shows on the display (Please refer to chapter error codes / troubleshooting).
- A retractable stand on the back of the instrument allows it to be used as a
bench top instrument.
1.2 Operation
Before switching on the instrument, connect the probe/s to the instru ment and
insert the battery (Please refer to chapter 2. Power supply/changing the battery).
A number an the instrument's housing marks each port.
1.3 Switching on and off
By operating the ON/OFF-key the instrument switched on or off. After switching
on the instrument indicates a full segment test for 15 seconds, then it starts to
function in measurement mode indicating the actual measurement value.
1.4 Menu
The adjustments of the instruments function: measurement value, calibration
of probes, deactivation of channels, for example, are selected from the menu
structure. Enter into the main menu by push ing (ENTER/ MENUE). Use the up
and down keys (
) to select the required menu. Push (ESC) to revert back
to the measuring mode.
1.
1. (ESC) key
2.
2. Up and down keys
3.
3. (ENTER/MENUE) key
12
Menu structure
12
12
12
12
12
13
0
13
13
14
14
R
17
17
S
18
T
18
18
RH
19
19
1.4.1 Measuring unit switching °C, °F and Resistance (Ohm's) (Unit)
19
Unit = Measuring unit
20
Measuring unit temperature (°C=Celsius, °F=Fahrenheit, o=Ohm)
To change the measuring unit push (ENTER/MENUE). Use the up and down
keys (
) to select Unit. Push again (ENTER/MENUE). On the right corner
of the display appears °C, °F or o. Use the up and down keys (
adjust the requested measuring unit and push (ENTER/MENUE) to confirm. Push
(ESC) to be back in the measuring mode.
1.4.2 Automatische Fühlererkennung (Smartprobes)
The Instrument detect Smartprobes with Eprom automatically. It is not necessary
to select this probes by the menu function Prob! After switching on the displays
option CAL 4 (1 sensor with Eprom) or CAL 44 (2 sensors with Eprom).
1.4.3 Probe selection / (Prob)
In case of using probes of the instrument series (P700-P770) please select
probes according to the following description.
Push (ENTER/MENUE) to change a probe. Use the up and down keys (
select Prob. Push (ENTER/MENUE) to confirm.
Unit
On the left corner of the display appears a small 1, which indicates the selected
channel. For changing the channel use the up and down keys (
again (ENTER/MENUE) to confirm. On the right corner of the display appears
the active probe. Use the up and down keys (
(ENTER/MENUE) to confirm the requested probe. Push (ESC) to be back in the
measuring mode.
oP 1
on
oP 2
oP 3
oP 4
MENUE
Prob
L in 2
CAL
ChnI
) to change the probe. Push
on
on
) again to
) to
Lo6
bLE
). Push
13

Publicité

Chapitres

Table des Matières
loading

Table des Matières