Maintenance - Abus Secvest Instructions D'installation Et D'utilisation

Sirène extérieure sans fil
Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 39

Maintenance

Maintenance
Caution
Before opening the sounder's cover, make sure that the alarm panel is in installer mode. This
should prevent the sounder being activated.
You should, however, be prepared for the fact that the sounder might nevertheless be acti-
vated. Make sure that any loud sounds emitted do not startle you, causing you to fall off the
ladder.
Test, during routine maintenance, that the sounder works properly.
Check the tamper contacts.
Check for signs of seeping water or insects and clean the device as required.
Replace the batteries every two years or if the alarm panel displays the message 'Flat battery in
outdoor sounder'. You can find the battery type to be used as a replacement under Technical
data.
Note:
Batteries and the device itself must be disposed of in accordance with the WEEE Di-
rective and applicable local and national regulations.
Note:
After removing the old batteries, wait 30 seconds before inserting the new batteries.
How to replace the batteries:
 Put the alarm panel in installer mode.
 Open the covers for the lid-fixing screws (see Fig. 1), loosen the screws and open the lid.
 Remove the jumper/connector cover (see Fig. 1) by pushing the two fixing tabs outwards
and lifting up the cover at the same time.
 Remove the battery connectors from the PCB and remove the batteries.
 Wait 30 seconds, insert the new batteries and connect them to the PCB (see Fig. 2).
Important
Insert the battery cables in the wire guides provided. Otherwise, the cables may be crushed.
 Put the jumper/connector cover back on, close the lid, tighten the cover fixing screws and
close the screws' covers.
 Test the system.