STANDARD SUPPLIED ACCESSORIES
Foot valve
OPERATION PRINCIPLE
INSTALLATION
Rev 3.0
2m PVC sunction
Injection valve
The functioning of the pump is insured by the action on the piston (C) of
the spring (B) and the electromagnet (A). In fact, the electromagnet, that
receives the electric impulses from the electronic circuit of the pump, puts
in movement the piston that is recalled in its initial position by the spring.
In such movement the piston drags with itself the membrane in teflon (D)
climbed on it, producing, because of the opening and closing of the
suction (E) and delivery valve (F), the expulsion of the present liquid
inside the pump head.
Cod. 00.009.307
1,5m PVC priming
hose
General rules
Position the pump as follows:
At a suitable height above the chemical up to a maximum
-
height of 1.5 meters.
If it's necessary to install the pump under the level of the
chemical, to avoid siphon problems, you need to use an
injection valve or an antisiphon valve.
-
Do not position the pump over the tank in presence of liquids
that emanate fumes unless it is hermetically closed.
At maximum temperature of 45°C, in a ventilated place and
-
easily accessible by an operator for periodical maintenance.
2m PE delivery hose
hose