The following operations must be done in order to avoid damages to the
mechanical components bearing the heavier work load and to keep your
water pressure cleaner performances efficient.
1) Important ! When the machine is new, the pump/motor set must be run
in for a short period. This running in consists of using the machine for
no more than 1 hour and to wait for 1 hour for its cooling; this operation
has to be done 4 or 5 times.
2) Check the pump and gear box oil level periodically, it must always be
higher than the rod notch. Change the gear box oil after the first 50
working hours, then every 500 hours. Change the pump oil after the
first 50 working hours, then every 500 hours. Use mineral base
SAE15/40 (Pump) and SAE 80/90 (Reducer). Motors have a
system called "Accert oil", its stop the motor if oil level is not
enough for the correct lubrification.
As concerns the motor, please refer to Loncin manual (KB) Lombardini
(KD) and Kholer (KXSB).
3) Do not leave the machine at very
low temperatures. The frost can
damage the pump and the
circuits. In case of long stay at
temperatures lower than 0 C the
operator must empty the circuits
and make the pump run for some
minutes with antifreeze liquid
reaching the pump through the
water suction hose. Whereas, too
high temperature can cause the
motor overheating when the
machine is working.
4) Do not suck corrosive liquids (paints, acids, solvents, very dense liquids)
as they could permanently damage the pump. After the use of detergents
or other liquids, always suck clean water to avoid deposits and scales.
5) Check and clean the water filter on the
pressure cleaner at least once a month.