( ﺍﻭ ﺯﺭ ﺇﻟﻐﺎﺀ ﻣﺆﻗﺖ ﺍﻻﻳﻘﺎﻑON TIMER CANCEL) 2. ﻹﻟﻐﺎﺀ ﻋﺮﺽ ﺍﻟﻜﻮﺩ، ﺍﺿﻐﻂ ﻭﺗﺎﺑﻊ ﺿﻐﻂ ﺯﺭ ﺇﻟﻐﺎﺀ ﻣﺆﻗﺖ ﺍﻟﺘﺸﻐﻴﻞ
.( ﳌﺪﺓ 5 ﺛﻮﺍﻥ. ﺍﻳﻀﺎ ﻳﻠﻐﻲ ﻋﺮﺽ ﺍﻟﻜﻮﺩ ﻧﻔﺴﻪ ﻓﻲ ﺣﺎﻟﺔ ﻋﺪﻡ ﺿﻐﻂ ﺍﻟﺰﺭ ﳌﺪﺓ 1 ﺩﻗﻴﻘﺔOFF TIMER CANCEL)
ﺍﳌﻌﻨﻰ
ﺍﳌﻘﺎﻭﻡ ﺍﳊﺮﺍﺭﻱ ﻟﻠﻬﻮﺍﺀ ﺍﳋﺎﺭﺟﻲ ﻗﺼﺮ/ﻣﻔﺘﻮﺡ
ﺍﳌﻘﺎﻭﻡ ﺍﳊﺮﺍﺭﻱ ﻷﻧﺒﻮﺏ ﺗﺼﺮﻳﻒ ﺍﻟﻀﺎﻏﻄﺔ ﻗﺼﻴﺮ/ﻣﻔﺘﻮﺡ/ﻓﻲ ﻏﻴﺮ ﻣﻜﺎﻧﻪ
ﺍﳌﻘﺎﻭﻡ ﺍﳊﺮﺍﺭﻱ ﻷﻧﺒﻮﺏ ﺍﻻﻣﺘﺼﺎﺹ ﻗﺼﺮ/ﻣﻔﺘﻮﺡ
ﺍﳌﻘﺎﻭﻡ ﺍﳊﺮﺍﺭﻱ ﳌﺒﺪﻝ ﺍﳊﺮﺍﺭﺓ ﺍﳋﺎﺭﺟﻲ ﻗﺼﻴﺮ/ﻣﻔﺘﻮﺡ
ﺍﳌﻘﺎﻭﻡ ﺍﳊﺮﺍﺭﻱ ﻟﻠﻤﺒﺪﻝ ﺍﳊﺮﺍﺭﻱ ﻟﻠﺘﺒﺮﻳﺪ ﺍﻟﺜﺎﻧﻮﻱ ﻗﺼﺮ/ﻣﻔﺘﻮﺡ
ﺍﳌﻘﺎﻭﻡ ﺍﳊﺮﺍﺭﻱ ﻷﻧﺒﻮﺏ ﺍﻟﺴﺎﺋﻞ ﻗﺼﺮ/ﻣﻔﺘﻮﺡ
ﺯﻳﺎﺩﺓ ﺗﺴﺨﲔ ﺟﺴﻢ ﺍﻣﺘﺼﺎﺹ ﻭﺗﻔﺮﻳﻖ ﺍﳊﺮﺍﺭﺓ
( ﺍﻟﻌﺎﻛﺲPCB ﺍﻟﺘﺤﻜﻢ ﺍﳋﺎﺭﺟﻲ ﻭPCB) ﺧﻄﺄ ﺍﺗﺼﺎﻝ
ﺍﳌﻘﺎﻭﻡ ﺍﳊﺮﺍﺭﻱ ﳉﺴﻢ ﺍﻣﺘﺼﺎﺹ ﻭﺗﻔﺮﻳﻖ ﺍﳊﺮﺍﺭﺓ ﻗﺼﻴﺮ/ﻣﻔﺘﻮﺡ
(IPM PCB ﺍﻟﺘﺤﻜﻢ ﺍﳋﺎﺭﺟﻲ ﻭPCB) ﺧﻄﺄ ﺍﺗﺼﺎﻝ
ﻋﺪﻡ ﻣﻼﺋﻤﺔ ﺗﺮﻛﻴﺐ ﺍﻷﻧﺎﺑﻴﺐ ﻭﺍﻷﺳﻼﻙ/ﺃﺳﻼﻙ ﺧﺎﻃﺌﺔ/ﻏﺎﺯ ﻏﻴﺮ ﻛﺎﻑ
.1. ﻳﺒﲔ ﹼ ﺻﻮﺕ ﺍﻟﺒﻴﺐ ﺍﻟﻘﺼﻴﺮ ﻣﻊ ﺻﻮﺗﻲ ﺍﻟﺒﻴﺐ ﺍﳌﺘﺘﺎﺑﻌﺔ ﻛﻮﺩﺍﺕ ﻏﻴﺮ ﻣﺘﻨﺎﻇﺮﺓ
٤
ﺧﻄﺄ ﻣﺴﺘﺸﻌﺮ ﺍﻟﻀﻐﻂ
ﺍﳌﻘﺎﻭﻡ ﺍﳊﺮﺍﺭﻱ ﻷﻧﺒﻮﺏ ﺍﻟﻐﺎﺯ ﻗﺼﺮ/ﻣﻔﺘﻮﺡ
ﺍﳋﺎﺭﺟﻲ ﻟﻠﻌﺎﻛﺲPCB ﺧﻄﺄ
ﺯﻳﺎﺩﺓ ﺗﺴﺨﲔ ﺻﻨﺪﻭﻕ ﺍﻟﺘﺤﻜﻢ ﺍﳋﺎﺭﺟﻲ
IGBT ﺧﻄﺄ
IPM ﺧﻄﺄ
/
ﺯﻳﺎﺩﺓ ﺗﻴﺎﺭ ﺍﻟﻀﺎﻏﻄﺔ ﺍﻟﻌﺎﻛﺴﺔ
ﻣﻨﻊ ﺯﻳﺎﺩﺓ ﺗﻴﺎﺭ ﺍﻟﻀﺎﻏﻄﺔ
ﺍﻟﻄﻮﺭ ﻣﻔﺘﻮﺡ ﺍﻭ ﻓﻮﻟﻄﻴﺔ ﻏﻴﺮ ﻣﺘﻌﺎﺩﻟﺔ
ﺧﻄﺄ ﺿﺒﻂ ﺍﻟﻘﺪﺭﺓ
ﺍﻟﻐﺎﺯ ﻏﻴﺮ ﻛﺎﻑ
ﺧﺎﺭﺝ ﺍﳌﺪﻯDC ﻓﻮﻟﻄﻴﺔ
ﺧﻄﺄ ﺍﺗﺼﺎﻝ
ﺧﻄﺄ ﺗﺮﻛﻴﺐ
(ﻣﻘﺎﻭﻡ ﺍﻟﺘﺠﻤﺪ )ﺍﻟﻐﺮﻑ ﺍﻷﺧﺮﻯ
ﺭﻣﺰ ﺍﳋﻄﺄ
H9
J1
J3
J5
J6
J7
J8
J9
L1
L3
L4
L5
L8
L9
LC
P1
P4
PJ
U0
U2
U4
U7
UA
UF
UH
ﻣﻼﺣﻈﺔ