Electrical Connection - OEM BM/2/AS Mode D'emploi Et D'entretien

Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

3.3 - ELECTRICAL CONNECTION (Fig. 6)
DANGER
The power feed line should be provided with a
suitable omnipolar DISCONNECTING SWITCH
(magnetothermic circuit-breaker and residual current
device) placed before the control unit main switch,
with a minimum contact opening of 3 mm.
THE LINE DISCONNECTING SWITCH must be
located near the machine so the operator can see
it at any moment while working on the machine or
performing maintenance or cleaning operations.
The earthing system should comply with the local
electric regulations in force.
The electric power cables should comply with
the maximum current required by the machine,
so that the total voltage drop at full charge will
be less than 2%.
The specifications of the electric power line
should correspond to the specifications of the
identification plate and to those mentioned in
the technical specifications table that can be
consulted in the first part of this booklet.
DANGER
Before connecting the machine with the electric
line, make sure that the DISCONNECTING SWITCH
is disconnected (line not energized), therefore:
• Connect the two connectors (1) and the ground con-
nector (2) connecting the two machines.
• Connect the power cable (3) of the machine with the
disconnecting switch placed above.
GB - 14
Installation and connections
FIG. 6
3
1
BM/2/AS
2

Publicité

Table des Matières
loading

Table des Matières