5.2
Deleting memory
6.1
Troubleshooting
during the measuring process, the arrhythmia symbol
voice function has been activated, the device speaks the memory location
number, together with the saved blood pressure and pulse values and the
blood pressure assessment as per the scale in the World Health Organisation
guidelines (see pg. 13).
Repeatedly pressing the MEM button
measured previously. In memory recall mode the unit switches off auto-
matically after approx. 120 seconds if the last entry has been reached and the
MEM button
has been pressed once more. Memory recall mode can be
exited at any time by pressing the START button
unit off. If all 60 memory locations in a memory are occupied, a new measured
value is saved whilst the oldest value is deleted.
If you are in memory recall mode, press and hold the MEM button
approximately 8 seconds. All measured data stored will be deleted automati-
cally after three beeps. Only noughts will be shown on the display instead of
the measured values.
The battery change symbol
• The batteries are too low or empty. Replace both batteries with new 1.5 V
AAA LRO3 batteries.
Erratic measurements being displayed
• Cuff incorrectly fitted or not tight enough. Fit cuff correctly and tighten.
• You have changed position or the cuff has moved during the measurement.
Keep still and do not move your arm or the cuff.
• You have an irregular heartbeat. Even if your heartbeat is only slightly
irregular, repeat the measurement. The unit is not suitable for people with
an extremely irregular heartbeat.
• You have spoken during the measurement, you are nervous or you are
excited. Do not speak and breathe deeply two or three times in order to
relax.
• You are not in the corrected seated position. Please assume the correct
position when taking the measurement.
• A problem occurred during inflation or during the measurement. Repeat
the measurement.
"EE" appears in the display
• The unit has not been inflated enough. Repeat the measurement
• A problem occurred during inflation or during the measurement. Repeat
the measurement.
No display or display locked
• No batteries have been inserted, batteries wrongly inserted or batteries are
completely empty. Insert batteries, check battery position or replace with
new batteries.
• A malfunction or fault has occurred. Briefly remove the batteries and then
replace them.
Please contact the service centre if the error message appears again
when the measurement is repeated.