Télécharger Imprimer la page

Mitsubishi Electric MSZ-GS06NA Manuel D'installation page 3

Masquer les pouces Voir aussi pour MSZ-GS06NA:

Publicité

1-4. INSTALLATION DIAGRAM
ACCESSORIES
Check the following parts before installation.
<Indoor unit>
(1)
Installation plate
Attachment screws for the installa-
(2)
tion plate
4 × 25 mm
(3)
Wireless remote controller
(4)
Felt tape (For left or left-rear piping)
(5)
Remote controller holder
Screws for the remote controller
(6)
holder
3.5 × 16 mm (Black)
(7)
Battery (AAA) for (3)
(8)
FIELD-SUPPLIED PARTS
(A)
Indoor/outdoor unit connecting wire*1
(B)
Extension pipe
(C)
Wall hole sleeve
(D)
Wall hole cover
(E)
Pipe attachment strap
(F)
Screw for (E) 4 × 20 mm
(G)
Piping tape
(H)
Putty
Drain hose
(or soft PVC hose, 19/32 in. [15 mm]
(I)
inner diameter or hard PVC pipe
VP16)
(J)
Refrigerant oil
(K)
Power supply cord *1
Note:
*1 Place indoor/outdoor unit connecting wire (A)
and power supply cord (K) at least 3 ft. (1 m)
away from the TV antenna wire.
4 in. (100 mm) or more when front
*2
and sides of unit are clear
When any 2 sides of left, right and
*3
rear of unit are clear
Units should be installed by licensed contractor
according to local code requirements.
Note:
• The dimensions indicated in the arrows (
show the required space to guarantee performance of
the air conditioner. Install the outdoor unit where the
maximum possible space can be provided, considering
later relocation, services, or repairs.
power usage may fall about 10% at the place where short
cycle is likely occur due to poor ventilation. Installing the
air outlet guide (optional) can improve performances.
• If air from the outlet blows against the wall, it may cause
stains on the wall.
Drain piping for outdoor unit
Install the unit horizontally.
Do not use drain socket in cold regions. Drain may freeze and make the fan stop.
The outdoor unit produces condensate during the heating operation. Select the installation place to ensure to prevent the outdoor unit and/or the grounds from being wet by drain
water or damaged by frozen drain water.
1
5
1
1
1
2
2
2
1
1
1
1
2 to 5
2 to 5
1
1
2 to 5
1
1
Do not take in the outlet air
) above
discharged by other units directly.
Use the wall hole sleeve
(C) to prevent indoor/
outdoor connecting wire
(A) from contacting metal
parts in the wall and to
protect the wiring from
rodents.
Unit: inch
31-1/2
5-15/16
19-11/16
Air inlet
1-9/16
Air outlet
×
2-3/8
13/16 slot
Wall hole cover (D)
Indoor unit
Seal the wall hole
gap with putty (H).
Wall hole
sleeve (C)
Attach the pipe to
wall with pipe at-
tachment strap (E).
Cut off the
Pipe attachment
extra length.
strap (E)
Attachment screw (F)
After the leak test, apply insulating mate-
rial tightly so that there is no gap.
When the piping is to be attached to a wall
comprised of tin plate or metal netting, use
chemically treated wooden piece 25/32 in.
(20 mm) or thicker between the wall and
the piping, or wrap insulation vinyl tape 7 to
8 turns around the piping.
To use existing piping, perform COOL
operation for 30 minutes and pump down
before removing the old air conditioner.
for new refrigerant.
Unit: mm
800
150
500
Air inlet
40
Air outlet
×
2-10
21 slot

Publicité

loading

Ce manuel est également adapté pour:

Msz-gs09naMsz-gs12naMsz-gs15naMsy-gs09naMsy-gs12naMsy-gs15na