Télécharger Imprimer la page

Beamz professional Panther 50 Led Spot Manuel D'instructions page 19

Publicité

Les langues disponibles
  • FR

Les langues disponibles

TROUBLE SHOOTING
Trouble
No response
from fixture when
power is applies
Fixture resets but
does not respond
correctly to
controller(DMX
mode operation)
Colours cannot
be mixed
Fixture does not
reset correctly
No light, lamp
cuts out
intermittently, or
burns out too
quickly
Probable cause(s)
No power to fixture
Primary fuse blown
Secondary fuse blown
Controller not connected
Incorrect addressing of
the fixtures
Bad data link connection
Conflict between
tracking and vector
control
Data link not terminated
Defective fixture or 2
devices transmitting on
link
Random color mixing is
on
Electronic or mechanical
failure
Lamp missing or blown
Fixture or lamp is too hot
Remedy
Check power cables
Replace fuse
Replace fuse
Connect controller
Check address setting on fixture and controller
Inspect cables and correct poor connections and/or
broken cables.
Eliminate scene cross-fade on controller
Insert termination plug in output of last fixture
Bypass fixtures one at a time until normal operation
is regained: unplug both connectors and connect
them directly together
Turn off random color mixing
Contact service technician
Disconnect fixture and replace lamp
Allow fixture to cool. If problem persists, contact
service technician
19

Publicité

loading

Ce manuel est également adapté pour:

150.463