1.
Component Overview
(Standard Delivery)..................... 8
2.

Please Read First!....................... 9

3.
Range of Application and
Pumping Media ........................... 9
4.
Safety ........................................... 9
4.1 Specified conditions of use ........... 9
4.2 General safety information............ 9
5.
Prior to Operation ..................... 10
5.2 Installation................................... 10
6.
Operation................................... 10
6.1 Automatic mode.......................... 10
6.2 Manual mode .............................. 10
7.
Care and Maintenance.............. 10
7.1 Periodic maintenance ................. 10
7.2 Pump storage ............................. 11
8.
Trouble Shooting ...................... 11
8.1 Fault finding ................................ 11
9.
Repairs....................................... 11
2. Please Read First!
These instructions are written in a way
that will enable you to safely use the
machine in a minimum of time. Here is
how to read the instructions:
Read these instructions completely
before use. Pay special attention to
the safety information.
These instructions are intended for
persons having a basic technical
knowledge
in
the
machines
such
as
described here. If you have no expe-
rience with this type of machine you
are advised to seek the advise of an
experienced individual before oper-
ating this machine.
Keep all documents supplied with
the machine for future reference.
Retain proof of purchase for possi-
ble warranty claims.
If you hire out or sell this machine be
sure to hand over the machine doc-
uments supplied.
The equipment manufacturer is not
liable for any damage arising from
disregard of these instructions.
The information in these instructions is
denoted as under:
Danger!
Warning
of
injury or environmental
damage.
Numbers in illustrations (1, 2, 3, ...)
indicate component parts;
are consecutively numbered;
refer to the corresponding num-
bers in brackets (1), (2), (3) ... in
the neighbouring text.
Instructions to be carried out in
sequence are numbered.
Instructions which can be carried
out in any sequence are preceded
by a bullet (•).
Listing are preceded by a M-dash (-).
3. Range of Application and
Pumping Media
This pump is intended for pumping water
in domestic applications, such as
pumping containers, sumps and
flooded basements;
fountain pumps;
circulation to avoid putrefaction;
feeding false rivulets and brooks.
A
Caution!
The max. permissible fluid
temperature is 35 °C.
handling
of
Pumping liquids containing abrasives
the
one
(such as sand) reduces the service
life of the pump.
4. Safety
4.1
Specified conditions of
use
This pump must not be used to supply
drinking water or for pumping foodstuff.
Explosive, flammable, aggressive fluids
or substances detrimental to health,
sewage must not be pumped.
This pump is not suitable for commercial
or industrial use.
Any other use is not as specified. Use
not as specified, alteration of the
machine or use of parts that are not
approved by the equipment manufac-
turer, can cause unforeseeable damage!
personal
Risk of electric shock!
Risk of personal injury
by electric shock.
Caution!
Risk of material damage
Note:
Supplementary information.
ENGLISH
4.2
General safety informa-
tion
Children, juveniles and persons not fam-
ilar with the instructions are not permit-
ted to operate the pump.
When used in swimming pools and gar-
den ponds and their range of protection,
the regulations according to DIN VDE
0100 -702, -738 are to be observed.
Also all local regulations pertaining to
the safe operation of submersible pumps
must be followed.
The following residual risks do principally
exist
when
operating
pumps and can not be fully eliminated -
even by employing safety devices.
A
Hazard by ambient conditions!
Do not use the pump in hazardous loca-
tions or near inflammable liquids and
gases!
B
Danger! Risk of electric shock!
Do not touch the plug with wet
hands! To unplug always pull at the
plug, not the power cable.
Connect only to an earthed outlet
that is properly installed, earthed
and tested. Mains voltage and fuse
protection must correspond to those
stated in the "Technical Specica-
tions".
Protection must be provided by a
residual current device (RCD) of
max. 30 mA capacity.
The earthed outlet or the plug con-
nection to an extension cable must
be located in an area safe against
flooding.
Use only extension cables of suffi-
cient lead cross section (see "Tech-
nical Specifications"). Unroll cable
reels fully.
Do not buckle, squeeze, drag or
drive over power cable and exten-
sion cables; protect from sharp
edges.
Place extension cable so that it can
not get into the fluid to be pumped.
Unplug:
prior to all servicing;
when persons are in the swim-
ming pool or garden pond.
A
Danger by pump failures!
If you notice shipping damage while
unpacking,
notify
your
immediately.
Do not operate the
machine!
Before each use check the pump,
especially the power cable and plug
for possible damage. Risk of fatal
electric shock!
submersible
supplier