Télécharger Imprimer la page

Yamaha Professional Serie Mode D'emploi page 8

Publicité

Les langues disponibles

Les langues disponibles

GENERAL SPECIFICATIONS
* These specifications are measured when the distortion of the AC Voltage is less than 1 %.
POWER OUTPUT LEVEL
Continuous average sine wave power with less than
0.05% THD. 20Hz - 20kHz
Stereo 8ft .
430W+430W
Stereo 4ft .
700W+700W
Mono 8ft. 1400W
FREQUENCY RESPONSE
Stereo, @ 8ft, 1W . 10Hz - 50kHz OdB +1 dB
Mono,
@
80,1W . 1 0Hz - 50kHz OdB +1 dB
POWER BANDWIDTH
Stereo, 215W, 8ft, 0.1% THD .10Hz - 100kHz
Stereo, 350W, 4ft, 0.1% THD .
10Hz - 100kHz
Mono, 700W, 8ft, 0.1% THD.10Hz - 100kHz
TOTAL HARMONIC DISTORTION
Stereo, 215W, 8ft,
20Hz - 20kHz... < 0.005%
Stereo, 350W, 4ft,
20Hz - 20kHz. <0.01%
Mono, 700W, 8ft,
20Hz - 20kHz... < 0.01%
INTERMODULATION DISTORTION
Stereo, 215W, 8ft,
60Hz:7kHz=4:1 . < 0.005%
Stereo, 350W, 4ft,
60Hz:7kHz=4:1
.... < 0.01%
Mono, 700W,
80
,
60Hz:7kHz=4:1 . < 0.01%
CHANNEL SEPARATION
{Input ATT max, input 600ft Shunt)
215W, 20Hz - 20kHz
@ 8ft . > 80dB
DAMPING FACTOR
1kHz @ 8ft. > 300
S/N
Input 600ft Shunt @ IHF-A ... >11 OdB
RESIDUAL NOISE
ATT at min, @ 12.7kHz, -6dB/oct LPF. < 75dB
ATT at min, IHF-A network. < 80dB
SLEW RATE
Stereo, 8ft. ±60V/pS, Full Swing
Mono, 8ft . ±100V/pS, Full Swing
SENSITIVITY
ATT max, 400W 8ft @ 1 kHz. +4dB (1,23V)
INPUT IMPEDANCE
Balanced/unbalanced
MAXIMUM VOLTAGE GAIN
Input ATT maximum, @ 1 kHz
METERS (PC4002M ONLY)
Large illuminated
peak level meters x 2 .
33.3d B
-50dB - +7dB
0dB = 160W @ 8ft
INDICATORS
Green signal LED x
(PC4002 only)
Red clip LED x 2 ...
Green BTL LED x 1
Red thermal fan .....
LED x 1
Red protection.
LED x 1
Red power LED x 1
2 . Illuminate when signal
outputlevel goes above 2V.
. Illuminate when output
distortion from channel
exceeds approx 1 %
. Illuminates when BTL
(mono) mode is selected
.. Illuminates during high¬
speed fan operation
. Illuminates during protection
or muting circuit operation
. Illuminates when power on
PROTECTION CIRCUIT
Muting. 6 sec (±2 sec) after power-on
DC sensing .. DC ±2V output voltage
PC limiter . RL < 2ft
Thermal . > 100°C Heat Sink Temp
COOLING FAN SPEED CIRCUIT
All temperatures refer to heat-sink temperature
Off to Low speed .. < 60°C
Low speed .. Cuts in above 60°C. Cuts
out when heat-sink temperature
drops below 45°C.
High speed. Cuts in above 80°C. Drops
to low speed when heatsink
temperature drops below 65°C.
POWER REQUIREMENTS
General model . 220/240V AC 50/60Hz
US&Canadian models . 120V AC 60Hz
POWER CONSUMPTION
General model . 1 600 W
US&Canadian models . 1600W, 2000VA
DIMENSIONS
(W x H x D) . 480 x 185.6 x 460 (mm)
(18-7/8-x 7 5/16-x 18-1/8")
WEIGHT
43 kg (94.8 lbs)
SUPPLIED ACCESSORIES
KNOB LOCK x 2
3mm, ALLEN KEY x 1
>15kft

Publicité

loading

Ce manuel est également adapté pour:

Professional pc4002Professional pc4002m