Télécharger Imprimer la page

CARLO GAVAZZI PD30CTD10BPIO Serie Manuel D'instructions page 29

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 89
Sensor
SSC
2) Dynamic teach command sequence
Dynamic teach for Single value teach command sequence
(Buttons are found in: "Teach-in SSC1" or "Teach-in SSC2" -> "Teach in dynamic SSC1" or
"Teach-in dynamic SSC2")
1. Press "Teach SP1 Start".
2. Move the target in and out of the detecting zone, at slightly different positions, in front of
the sensor.
3. Press "Teach SP1 Stop"
4. Teach-in result is shown in "Teach-in Result. -> Teach-in State" e.g . "SUCCESSS"
5. QoT is shown in "Quality of Teach" e.g. 150 %
3) Two value teach command sequence
Two Value teach for SP1
(Buttons are found in: "Teach-in SSC1" or "Teach-in SSC2" -> "Teach-in Two value SSC1" or
"Teach-in Two value SSC2")
1. Move the target to the position for SP1 TP1
A. Press "Teach SP1 TP1"
B. "Teach-in Result.TeachPoint 1 of Set Point 1" = e.g. "OK"
C. Teach-in Result.Teach-in state = e.g. "WAIT FOR COMMAND"
2. Move the target to the position for SP1 TP2
A. Press "Teach SP1 TP2".
B. Teach-in Result.TeachPoint 2 of Set Point 1" = e.g. "OK"
C. Teach-in Result. -> Teach-in State e.g . "SUCCESSS"
3. QoT is shown in "Quality of Teach" e.g. 150 %
Sensor
SSC
Hysteresis
SP1
TP1
ON
Hysteresis
TP2
SP1
ON
Sensing distance
OFF
Sensing distance
TP1
OFF
Rev.01 - 08.2022 | MAN PD30CTD IO-Link ENG | © 2022 | CARLO GAVAZZI Industri
29

Publicité

loading