3. Remove the jumper (JP1) from the control board. (This activates the power vent function).
4. Replace the control board cover and all wire harness connections except for the power cord (x1), it will be replaced with
the new wire harness (provided).
5. Connect the new wire harness in locations (x1) and (x12) as shown on the top of the control board.
6. Cut the yellow wire loop (APS) located in (x5) and connect one end to the orange wire and the other end to the red wire of
the new wire harness. Secure grounds to the base.
BATTERY HOLDER COMPLETE
WITH PROGRAM BUTTON
7. Connect the other end to the wire harness provided with the GPV.
8. Test your appliance by turning it on using the remote.
note:
There is a 15 second pre-purge before the burner will light and a 120 second post-purge once the appli-
ance is turned off before the blower stops.
Wolf Steel Ltd., 24 Napoleon Rd., Barrie, ON L4M 0G8 Canada
PILOT
THERMAL SENSOR
THERMAL SENSOR
X5
WIRE HARNESS
(APS)
YELLOW
LOOP CUT
IN HALF
ORANGE
RED
RESET BUTTON
X1
GREEN
X12
BLACK
WHITE
BLACK
GPV
1(866)820-8686
www.napoleon.com
W415-4075 / A / 02.09.22