PVA-47X Power Vent Adaptor Kit Installation Instructions
These instructions are to be used in conjunction with those for the GPV and your appliance.
This information supercedes that your appliance installation manual.
You will need:
Included in PVA-47X:
W500-0551
W750-0445
Terminal Installation
Refer to GPV installation instructions
VENT LENGTHS
When installing the venting, these parameters supersede the Vent Installation
Section in the appliance's Installation and Operating Instructions, use the
following guidelines:
Maximum horizontal vent run with no rise is 70 feet total.
H = HORIZONTAL RUN
MAX H+V
70 FEET
Wolf Steel Ltd., 24 Napoleon Rd., Barrie, ON L4M 0G8 Canada
INSTALLER: Leave these instructions with the appliance.
CONSUMER: Retain these instructions for future reference.
Plate, dilution
Wire, Linear Power Vent (3')
V = VERTICAL RUN
MIN H+V
MAX ELBOWS
10 FEET
SIX 90°
1(866)820-8686
www.napoleon.com
W415-4075 / A / 02.09.22

Publicité

loading

Sommaire des Matières pour Wolf Steel PVA-47X

  • Page 1 Maximum horizontal vent run with no rise is 70 feet total. H = HORIZONTAL RUN V = VERTICAL RUN MAX H+V MIN H+V MAX ELBOWS 70 FEET 10 FEET SIX 90° W415-4075 / A / 02.09.22 Wolf Steel Ltd., 24 Napoleon Rd., Barrie, ON L4M 0G8 Canada 1(866)820-8686 www.napoleon.com...
  • Page 2 Under certain situations (longer vents), it may be necessary to add a dilution plate to the bottom portion of the gas power vent. W415-4075 / A / 02.09.22 Wolf Steel Ltd., 24 Napoleon Rd., Barrie, ON L4M 0G8 Canada 1(866)820-8686 www.napoleon.com...
  • Page 3 2. Using a flat head screwdriver carefully release the 4 tabs (2 per side) to remove the top cover from the control board. note: It may be easier to remove the control board from the appliance. W415-4075 / A / 02.09.22 Wolf Steel Ltd., 24 Napoleon Rd., Barrie, ON L4M 0G8 Canada 1(866)820-8686 www.napoleon.com...
  • Page 4 There is a 15 second pre-purge before the burner will light and a 120 second post-purge once the appli- ance is turned off before the blower stops. W415-4075 / A / 02.09.22 Wolf Steel Ltd., 24 Napoleon Rd., Barrie, ON L4M 0G8 Canada 1(866)820-8686 www.napoleon.com...
  • Page 5 La déviation horizontale maximale sans élévation est de 70 pieds en tout. H = COURSE HORIZONTALE V = COURSE VERTICALE MAX H+V MIN H+V MAX COUDES 70 PIEDS 10 PIEDS SIX 90° W415-4075 / A / 02.09.22 Wolf Steel Ltd., 24 Napoleon Rd., Barrie, ON L4M 0G8 Canada 1(866)820-8686 www.napoleon.com...
  • Page 6 Dans certain situations (évacuation plus long), il pourrait être nécessaire d’ajouter une plaque de dilution à la portion du bas du terminaison mécanique de gaz. W415-4075 / A / 02.09.22 Wolf Steel Ltd., 24 Napoleon Rd., Barrie, ON L4M 0G8 Canada 1(866)820-8686 www.napoleon.com...
  • Page 7 2. Avec l’aide d’un tournevis à tête plâte, soigneusement relâcher les 4 pattes (2 par côté) pour enlever le couvercle du panneau de contrôle. note: Il peut être plus facile d’enlever le panneau de contrôle. W415-4075 / A / 02.09.22 Wolf Steel Ltd., 24 Napoleon Rd., Barrie, ON L4M 0G8 Canada 1(866)820-8686 www.napoleon.com...
  • Page 8 Il y a une deuxième purge de 15 secondes préalable avant que le brûleur s’allume et une purge après 120 seconds quand l’appareil est éteint avant l’arrêt de la soufflerie. W415-4075 / A / 02.09.22 Wolf Steel Ltd., 24 Napoleon Rd., Barrie, ON L4M 0G8 Canada 1(866)820-8686 www.napoleon.com...