REMOTE CONTROL
(Software version 07.04.07)
1. back button
(previous screen)
2. knob
3. OK button
(to confi rm operation
or access main menu)
4. DISPLAY
USER MENU
Press the OK button to access the Menu. Use the knob in the centre
to scroll through the menu list and select a parameter, then press OK
to confirm.
SYSTEM OPERATION MODE
Summer
OFF
COMPLETE MENU
DOMESTIC HOT WATER SETTINGS
DHW comfort setpoint temperature
Time Programming
Domestic Hot Water Program
- Set Comfort T
- Set Reduced T
- Set Time Prog
- DHW Pre-heating
Auxiliary Timer
- Set Comfort T
Comfort function
- Disabled
- Time Based
- Always Active
Thermal cleanse function
- Thermal cleanse function
- Thermal Cleanse target temp
Operation mode
- Green
- Comfort
- Fast
- I-memory
- HC-HP
Domestic Hot Water BOOST
- OFF
- ON
Holiday Function
- OFF
- ON
SPECIAL MODE
HPWH Quiet Mode Activation
- OFF
- ON
PV setpoint temp.
SYSTEM PERFORMANCES
Energy Metering
Consumptions history
- DHW
DHW temperature (T dome) (non disponibile)
2 / EN
OK
1
2
3
4
TECHNICAL AREA
- Simultaneously press the back "
code" appears on the display.
- Turn the knob to enter the technical code (234) then press OK;
the display will show TECHNICAL AREA.
- Turn the knob and select: COMPLETE MENU.
Press the OK button. Turn the knob and select menu: 33 HPWH
Parameters, press the OK button.
DESCRIPTION
33
HPWH Parameters
33 0
User parameters
33 0
0
Operation Mode
P16
33 0
1
Quiet Mode
U8
P15
33 0
2
Acoustic touch feedback
33 0
3
Domestic hot water boost
U3.2 33 0
4
DHW preheating
33 1
Advanced settings
P10
33 1
0
Tank capacity
P6
33 1
1
I - memory comfort temperature
P8
33 1
2
Min temperature air HP
P7
33 1
3
Max temperature HP
P9
33 1
4
Hyst temperature HP
33 2
Input output configuration
P1
33 2
0
HC - HP mode
P11
33 2
1
Photovoltaic integration
P12
33 2
2
PV setpoint temperature
P13
33 2
3
SG mode
33 3
System settings
P14
33 3
0
Hydraulic scheme
33 4
Domestic Hot Water
+ / -
33 4
0
DHW comfort setpoint temp.
U3.1
33 4
1
DHW reduced setpoint temp.
P4
33 4
2
Max T
P5
33 4
3
Min T
U1
33 4
4
Comfort Function
P1
33 4
5
Max heating time
P2
33 4
6
Thermal cleanse function
U5
" and "OK" buttons until "Enter
RANGE
0. Green
1. Comfort
2. Fast
3. I-memory
4. HC - HP
OFF - ON
OFF - ON
OFF - ON
OFF - ON
0. OFF
1. HC - HP
2. HC - HP 40
3. HC - HP 24h
0. OFF
1. Heat Pump
2. HP + HE1
3. HP + HE1 + HE2
OFF - ON
0. Only HP
1. Auxiliary
2. Preheater
3. HP system
0. Disabled
1. Time based
2. Always active
OFF - ON

Publicité