Troubleshooting Guide - DOSMATIC The Advantage A10-10% Manuel D'installation Et D'utilisation

Doseur
Table des Matières

Publicité

TROUBLE SHOOTING GUIDE
Please check out our website at
www.dosmatic.com for more
information about troubleshooting.
You can also call us at 1-800-344-
6767 (US and Canada) or 972-245-
9765.
If no "clicking" sound:
CHECK UPPER PUMP END
1. If water flow rate exceeds Rated
Service Flow of injector, reduce flow
rate to less than Rated Service Flow.
2. If operating pressure exceeds max.
limit, install a pressure reducer valve.
3. Replace #17 O-Ring if leaking.
4. Main Piston Assy. #9 wearing:
Replace #9 and install a 140 mesh
filter to remove abrasive particles
from water.
5. Cover #1 or Main Body #40 bores
are wearing or scored. Lightly sand
inside diameter of bores to remove
scoring or grooves. Install a 140 mesh
filter to remove abrasive particles
from water.
PROCEDURE DE CONTRÔLE
S'il vous plait veuillez consulter notre
website: www.dosmatic.com pour plus
d'informations sur la PROCEDURE DE
CONTRÔLE.
Vous pouvez également contacter votre
revendeur.
Si vous n'entendez plus le bruit
«click»
VERIFIEZ LA PARTIE HAUTE
DU DOSEUR
1
Si le débit de l'eau est supérieur
au débit indiqué pour le doseur, le
diminuer dans le cadre des débits de
fonctionnement indiqués.
2. Si la pression dépasse celle maximale
autorisée: installer un limiteur de
pression.
3. En cas d'usure remplacer le joint #17
4. Ensemble piston moteur #9 usé: le
remplacer, et installer un filtre à 100µ
en amont du doseur, afin de retenir les
particules abrasives contenues dans
l'eau.
5. La surface interne du demi corps
supérieur #1 ou du demi corps
inférieur #40 est abîmée : Passer
délicatement au papier de verre pour
éliminer les rayures. Installer un filtre
à eau 100 µ pour retenir les particules
abrasives de l'eau.
10

Publicité

Table des Matières
loading