Maintaining the temperature
Once the set temperature is reached, you can reduce the filtration period according to the
temperature requirements (8 to 10 hours a day minimum during the summer). The heat pump
will re-start automatically when necessary.
The minimum working time change during the period, contact your seller for more information.
If the temperature decreases and the machine works every time the filtration pump is
working: increase the filtration time.
You have to use a thermal pool cover in order to avoid unnecessary heat loss.
IMPORTANT: A pool without any cover will loose 4 times more energy than a pool with
a cover.
The calculation of the adequate heat pump is always including a swimming pool cover.
Maintenance (by a qualified technician)
Before any maintenance operation, the heat pump must be completely stopped for few
minutes before connecting pressure controllers. This is because high pressure and
temperature inside the heat pump could be harmful.
Please check the following on a monthly basis:
• Check and clean the evaporator (with a soft brush or water jet).
Do not use high pressure cleaner.
• Check all electrical and ground connections.
• Check that all electrical connections and terminals are securely connected.
• Check gas pressure (when heat pump is stopped, manometer must indicate a pressure
higher than 0.5)
Please check the following points weekly:
• Check settings.
• Check securities.
• Check all electrical connections and ground.
• Check condenser cleanliness.
Use soft soap and water to clean the heat pump casing.
Do not use solvents.