Télécharger Imprimer la page

Publicité

Liens rapides

CCT SELECTABLE LED
LINEAR T8 TYPE B LAMPS
Models: S11919, S11929, S11969
INSTALLATION AND SAFETY INSTRUCTIONS
IMPORTANT: Read before installing fixture. Retain for future reference.
WARNING:
• DANGER: Risk of shock-disconnect power before
installation.
• WARNING: Risk of fire or electric shock. LED
Retrofit Kit installation requires knowledge of luminaire
electrical systems. If not qualified, do not attempt
installation. Contact a qualified electrician.
• WARNING: Product must be installed in accordance
with the national electrical code or your local electrical
code. If you are not familiar with these codes and
requirements, contact a qualified electrician.
• WARNING: Install this kit only in luminaries that have
the construction features and dimensions shown in the
photographs and/or drawing and where the input rating
of the retrofit kit does not exceed the input rating of
the luminaire.
• WARNING: To prevent wiring damage or abrasion,
do not expose wiring to edges of sheet metal or other
sharp objects.
• WARNING: NOTE: Shunted lamp holders are found
only in fluorescent luminaries with instant-start
ballasts. Instant-start ballasts can be identified by the
words "Instant Start" or "I.S." marked on the ballast.
This designation may be in the form of a statement
pertaining to the ballast itself, or may be combined
with the marking for the lamps with which the ballast
is intended to be used, for example F40T 12/IS, for
more information contact the LED luminaire retrofit kit
manufacturer.
Do not make or alter any open holes in an enclosure of
wiring or electrical components during kit installation.
Installers should not disconnect the existing wire from
lampholder terminals to make new connections at
lampholder terminals. Instead installers should cut
existing lampholder leads away from the lampholder
and make new electrical connections to lampholder
lead wires by employing applicable connectors.
The units covered by this report were intended to retrofit surface mount, Type IC or non-IC recessed mount Listed fluorescent
luminaires that use maximum 4 tubular lamps, the minimum lamp compartment dimensions are tabulated below.
Item
Description
Number
S11919
12.5T8/LED/48/840-850-865/BP/2PK
S11929
12.5T8/LED/48/840-850-865/BP
S11969
12.5T8/LED/48/830-835-840/BP
© Copyright 2022 Satco Products, Inc. 3/22 v4.0
• WARNING: Luminaire wiring and electrical parts
may be damages when installing retrofit kit hardware.
Check for enclosed wiring and components.
• WARNING: Check the existing wiring for damage
before installing upgrade kit. Do not install if existing
wires are damaged.
This retrofit kit is accepted as a component of a
luminaire where the suitability of the combination shall
be determined by authorities having jurisdiction.
THIS RETROFIT KIT INCLUDES, LED TUBE,
OPERATING INSTRUCTIONS, AND FIXTURE LABEL
FOR THE DOUBLE OR SINGLE ENDED APPLICATION.
• "This luminaire has been modified and can no longer
operate the originally intended lamp," shall be marked
on the retrofit luminaire where readily visible by the user
during normal maintenance including lamping.
• Do not use with dimmers.
• Suitable for damp locations.
• Suitable for use in enclosed luminaries, not vapor tight.
• Suitable for use with the following emergency
equipment; SATCO Products, Inc., model S8000,
S8002; 5Watt or 10 Watt Emergency LED Driver.
• This device complies with Part 15 of the FCC rules.
Operation is subject to the following two conditions:
(1) This device may not cause harmful interference,
and (2) This device must accept any interference
received, including interference that may cause
undesired operation.
CCT
Watts
Hours
40-50-65K
12.5W
50,000
30-35-40K
1
Minimum Lamp
Lumens
Compartment Dimensions
(Length x Width x Height)
47 7/8 x 23 7/8 x 4 inches
1800
(121.5 x 60.5 x 10 cm)
Lamp-to-Lamp
Spacing
4 3/8 inches
(11cm)
Satco Products, Inc.
Brentwood, NY 11717

Publicité

loading

Sommaire des Matières pour Satco NUVO S11919

  • Page 1 47 7/8 x 23 7/8 x 4 inches 4 3/8 inches S11929 12.5W 50,000 1800 12.5T8/LED/48/840-850-865/BP (121.5 x 60.5 x 10 cm) (11cm) S11969 12.5T8/LED/48/830-835-840/BP 30-35-40K Satco Products, Inc. © Copyright 2022 Satco Products, Inc. 3/22 v4.0 Brentwood, NY 11717...
  • Page 2 3. Remove lens and wiring compartment, if applicable. 4. Cut all wires connected to the ballast as shown below and remove ballast. 5. Identify what type of lampholders are in fixture. Single-Ended wiring installation of SATCO tubes requires non-shunted G13 lampholders.
  • Page 3 STEP 5: Reinstall wiring compartment cover. STEP 6: Install all of the SATCO tubes, making sure Side A in installed in the lampholders wired to the line and neutral. Install LED tubes so that the LEDs are pointed in the proper direction for illumination, and install any lens or diffuser as applicable.
  • Page 4 NOTE: There should not be any exposed wires from sockets left unconnected. STEP 5: Reinstall wiring compartment cover. STEP 6: Install all of the SATCO tubes. Install LED tubes so that the LEDs are pointed in the proper direction for illumination, and install any lens or diffuser as applicable.
  • Page 5 PASO 5: Vuelva a instalar la cubierta del compartimento de cableado. PASO 6: Instale todos los tubos SATCO, asegurándose de que el Lado A esté instalado en los portalámparas conectados a la línea y al neutro. Instale los tubos LED de forma que los LED apunten en la dirección adecuada para la iluminación, e instale cualquier lente o difusor según corresponda.
  • Page 6 ÉTAPE 5: Réinstaller le couvercle du compartiment de câblage. ÉTAPE 6: Installez tous les tubes SATCO, en vous assurant que le côté A est installé dans les douilles câblées à la ligne et au neutre. Installer les tubes à DEL de sorte que les DEL soient pointées dans la direction appropriée pour l’éclairage et installer toute lentille ou tout diffuseur, le cas échéant.

Ce manuel est également adapté pour:

Nuvo s11929Nuvo s11969