Usage:
Filter fans are used for cooling stationary, closed electric cabinets of protection class I.
Installation guidelines:
Installation is performed in accordance with the installation diagram in the sequence 1 to 4. The enclosure cutout (1) is to be
made in accordance with the included template. The mounting frame (2) is to be fitted with self−adhesive sealing band. The
protective film is to be removed from the sealing band prior to installation. The fastening screws for the mounting frame are
included in the delivery. The hood blades (4) must point downward. The electrical connection is made by means of pressure
clamps. When installing EMC filter fans, ensure good metallic contact between the enclosure cut−out (1) and the contact spring
band on the mounting frame (2). Operating temperature range: −40 °C to 70 °C (−40 °F to 158°F).
Function:
The cooling function is ensured only in combination with an exit filter (optional with axial fan). Notice: A heavily soiled filter mat
results in reduction in cooling performance. In the standard version, the air direction is from the outside to the inside. By turning
the axial fan, the air direction is reversed.
Maintenance:
The degree of soiling of the filter mat must be monitored. Replace, blow out, or beat the filter mat as necessary. To do this, pull off
the hood (4), which is secured with snap clips.
Accessories:
Exit filter
Replacement filter mats
Thermostat
Airflow monitor
- 2 -
© 2018 Hoffman Enclosures Inc.
WARNING
The filter fan should only be installed by qualified technicians in accordance with the respective
national power–supply guidelines.
The safety and protection against incidental contact is to be ensured through proper
installation.
The technical specifications on the type plate must be observed!
L'installation du ventilateur à filtre ne doit être faite que par un personnel qualifié dans le
respect desrèglements locaux en vigueur concernant l'alimentation électrique.
Le montage doit garantir le respect des normes de sécurité et la protection contre les contacts
accidentels.
Observer les spécifications techniques figurant sur la plaque signalétique
La instalación del ventilador con filtro se realizará solamente por personal calificado, bajo el
cumplimiento de las directivas locales de alimentación de corriente.
Mediante el montaje se deben asegurar las medidas de protección y la protección contra
contactos.
¡Observar los datos técnicos en la placa de características!