5) I/O Mapping Example
Example:
Assumed Settings
- Single Z-Boards
used with single solenoid
TM
valves
- Double Z-Boards
used with double
TM
solenoid valves
- Manifold I/O Size = ½ Rack
- Starting Quarter = 1st
- Valve Output Configuration = 32 Coils
Discrete I/O Configuration
Pos
Module Type
Part No.
No.
1
MCM
239-1384
8O Sourcing
2
239-1315
(PNP)
16O Sourcing
3
239-1319
(PNP)
4I Sinking
4
239-1304
(NPN)
8I Sinking
5
239-1308
(NPN)
Manifold I/O Configuration
Outputs and Mapping Location
Valve Outputs = 12
Word 0; Bits 0-11
Allocated Unused
Word 0; Bits 12-15
Valve Outputs = 20
Word 1; Bits 0-15
Discrete
Word 2; Bits 0-15
Outputs = 24
Word 3; Bits 0-7
Total Outputs = 56
Inputs and Mapping Location
Discrete Inputs = 12
Word 0; Bits 0-3, 8-15
Allocated and
Word 0; Bits 4-7
Reserved Inputs = 4
Total Inputs = 16
All manuals and user guides at all-guides.com
G2-2 Series A-B 1771 Remote I/O
Quick Start Manual
In
Out
Bits
--
--
--
8
--
16
4
--
8
--
When the 12 End
energized, the 2 port
is pressurized.
3835050 TDG22ABQS3-0
Subject to change without notice
www.numatics.com/fieldbus
When the 14 End
Solenoid is
Solenoid is
energized, the 4 port
is pressurized.
1/07
Page 5

Publicité

loading