Model KPED892K Exterior Blower
Installation Instructions and Use and Care Guide
IMPORTANT:
READ AND SAVE THESE INSTRUCTIONS.
The installer must leave these instructions with the homeowner. The homeowner must keep these instructions for future
reference and for local electrical inspectors use.
Before you start...
Your safety and the safety of
others are very important.
We have provided many important safety
messages in this manual and on your
appliance. Always read and obey all safety
messages.
This is the safety alert symbol.
This symbol alerts you to
potential hazards that can kill
or hurt you and others.
All safety messages will follow the safety
alert symbol and either the word
"DANGER" or "WARNING". These
words mean:
Important: Observe all governing
codes and ordinances.
Proper installation is your responsibility.
Make sure you have everything
necessary for correct installation. It is
the responsibility of the installer to
comply with the clearances specified.
To avoid damage to motor bearings
and impellers, keep drywall spray,
construction dust, etc. away from the
exterior blower.
Care of your
exterior blower
Disconnect power supply and lock out
service panel before cleaning or
servicing.
To clean, remove cover and vacuum
blower and housing, being careful not
to damage blower wheel.
The motor is permanently lubricated.
Do not oil or disassemble.
DANGER
You can be killed or seriously injured if
you don't immediately follow instructions.
WARNING
You can be killed or seriously injured if
you don't follow instructions.
All safety messages will tell you what the
potential hazard is, tell you how to reduce
the chance of injury, and tell you what can
happen if the instructions are not followed.
IMPORTANT
Before installing exterior mounted
blower, read the installation instructions
for the Kitchen downdraft system of
range hood that will be used in
conjunction with this power system.
The exterior blower is factory set at
900 cfm (424.7 l/s).
This fan is suitable for use with solid-
state speed controls.
Electrical
requirements
Important: Observe all governing
codes and ordinances.
It is the customer's responsibility:
• To contact a qualified electrical
installer.
• To assure that the electrical installation
is adequate and in conformance with
National Electrical Code, ANSI/NFPA
70 — latest edition*, or CSA
Standards C22.1-94, Canadian
Electrical Code, Part 1 and C22.2
No.0-M91 - latest edition** and all local
codes and ordinances.
If codes permit and a separate ground
wire is used, it is recommended that a
qualified electrician determine that the
ground path is adequate.
Do not ground to a gas pipe.
Check with a qualified electrician if
you are not sure exterior blower is
properly grounded.
Do not have a fuse in the neutral or
ground circuit.
A.
A 120-volt, 60-Hz, AC-only supply
wired for 15 amp service is required.
B.
The blower motor must be
connected with copper wire only.
Copies of standards listed may be
obtained from:
* National Fire Protection Association
One Batterymarch Park
Quincy, Massachusetts 02269
** CSA International
8501 East Pleasant Valley Road
Cleveland, Ohio 44131-5575
Page 1

Publicité

loading

Sommaire des Matières pour KitchenAid KPED892K

  • Page 1 Model KPED892K Exterior Blower Installation Instructions and Use and Care Guide IMPORTANT: READ AND SAVE THESE INSTRUCTIONS. The installer must leave these instructions with the homeowner. The homeowner must keep these instructions for future reference and for local electrical inspectors use.
  • Page 2 Venting Maximum length of The blower motor must be requirements vent system connected to the downdraft vent system wiring as described in the Vent Length downdraft vent system instructions for Determine which venting method is best connecting the exterior blower motor 10"...
  • Page 3 Now start... Mark a 27-1/2" x 34" (69.9 x Go to "Making electrical and 86.4 cm) rectangle on wall as indicated vent connections", Page 4. in FIGURE 1. WARNING Cut a rectangular hole in the Excessive Weight Hazard siding only. Do not cut sheathing. Nail ROOF INSTALLATIONS Use two or more people to move down all siding ends.
  • Page 4 roofing cement. If you are installing external Remove the cover from the exterior Top and side flanges of the back plate blower on a flat roof: blower. Then remove the wiring box cover. may be covered with trim. It is 2 x 4 framing recommended that electrical connection recommended...
  • Page 5 Outside the United States and Canada, a different warranty may apply. For details, please contact your authorized KitchenAid dealer. Additional help can be found by checking the “Requesting Assistance or Service” section or by calling our KitchenAid Customer Interaction Center, 1-800-422-1230 (toll-free), from anywhere in the U.S.A. or Canada. Page 5...
  • Page 6 Consumer Relations Department KitchenAid Canada 1901 Minnesota Court Mississauga, Ontario L5N 3A7 Part No. 4329489/8284825 Rev. B Pièce N° 4329489/8284825 Rév. B © 2002 KitchenAid ® Registered trademark/™ trademark of KitchenAid, U.S.A., KitchenAid Canada licensee in Canada Printed in Italy...
  • Page 7 Modèle KPED892K Ventilateur d'extraction Instructions d'installation et Guide d'utilisation et d'entretien IMPORTANT : LIRE ET CONSERVER CES INSTRUCTIONS. Installateur : Remettre les instructions d’installation au propriétaire de l’appareil. Propriétaire : Conserver les instructions d’installation pour consultation ultérieure et à l’intention de l’inspecteur local des installations électriques.
  • Page 8 Circuit d’évacuation Longueur maximale du circuit d’évacuation On doit raccorder le moteur du de l’air ventilateur au câblage du système Taille des conduits Longueur d’aspiration par le bas conformément à Déterminer la configuration d’évacuation la description présentée dans les Dia. 25,4 cm (10 po). 16,8 m (55 pi) la mieux adaptée à...
  • Page 9 Commencez Tracer sur le mur un rectangle de Calfeutrer autour de la tête maintenant… 69,9 x 86,4 cm (27 1/2 x 34 po) – voir la de chaque vis de fixation. FIGURE 1. AVERTISSEMENT Passer à l’étape Découper une ouverture «Raccordement du câblage électrique Danger -Poids excessif rectangulaire dans le parement...
  • Page 10 Pour l’installation du ventilateur Les sections supérieure et latérales du solin peuvent être recouvertes d’une extérieur sur un toit plat : Enlever le couvercle du ventilateur garniture. On recommande de réaliser extérieur. Enlever ensuite le couvercle de cadre de support d’abord et contrôler le raccordement la boîte de raccordement.
  • Page 11 G. Au Canada, frais de déplacement ou de transport pour les clients qui résident dans des régions éloignées. KITCHENAID ET KITCHENAID CANADA NE SONT PAS RESPONSABLES POUR LES DOMMAGES FORTUITS OU INDIRECTS. Certains États ou certaines provinces ne permettent pas l’exclusion ou la limitation des dommages fortuits ou indirects de sorte que cette exclusion ou limitation peut ne pas s’appliquer dans votre cas.
  • Page 12 1901 Minnesota Court le jour. problème au : Mississauga, Ontario L5N 3A7 Pièce N° 4329489/8284825 Rév. B © 2002 KitchenAid ® Marque de commerce déposée de KitchenAid, U.S.A., utilisée sous licence au Canada par KitchenAid Canada Imprimé en Italie...