Product Information
The dehumidifier is used to remove excessive moisture from the air. The resulting reduction in
relative humidity protects buildings and their contents from the adverse effects of excess
humidity.
The environmentally friendly R290 is used as the refrigerant. R290 has no damaging influence
on the ozone layer (ODP), a negligible greenhouse effect (GWP) and is available worldwide.
Because of its efficient energy properties, R290 is highly suitable as a coolant for this
application. Special precautions must be taken into consideration due to the coolant's high
flammability.
Safety Instructions
This appliance can be used by children aged from 8 years and above and persons with reduced
physical, sensory or mental capabilities or lack of experience and knowledge if they have been
given supervision or instruction concerning use of the appliance in a safe way and understand the
hazards involved. Children shall not play with the appliance. Cleaning and user maintenance shall
not be made by children without supervision.
The unit is designed only for use with R-290 (propane) gas as the designated refrigerant.
THE REFRIGERANT LOOP IS SEALED. ONLY A QUALIFIED TECHNICIAN SHOULD
ATTEMPT TO SERVICE!
Do not discharge the refrigerant into the atmosphere. R-290 (propane) is flammable and heavier
than air.
It collects first in low areas but can be circulated by the fans.
If propane gas is present or even suspected, do not allow untrained personnel to attempt to find
the cause.
The propane gas used in the unit has no odor.
The lack of smell does not indicate a lack of escaped gas.
If a leak is detected, immediately evacuate all persons from the store, ventilate the room and
contact the local fire department to advise them that a propane leak has occurred.
Do not let any persons back into the store until the qualified service technician has arrived and
that technician advises that it is safe to return to the store.
No open flames, cigarettes or other possible sources of ignition should be used inside or in the
vicinity of the units.
Component parts are designed for propane and non-incentive and non-sparking. Component
parts shall only be replaced with identical repair parts.
If the supply cord is damaged, it must be replaced by the manufacturer, its service agent or
similarly qualified persons in order to avoid a hazard.
The appliance shall be disconnected from its power source during maintenance. Ensure the unit is
far away from fire, inflammable, or explosive objects.
Do not use means to accelerate the defrosting process or to clean, other than those
recommended by the manufacture.