Télécharger Imprimer la page

Publicité

Liens rapides

PREMIUM LED T8
BALLAST BYPASS
Models: S11910, S11911, S11912, S11913,
S11914, S11915, S11916, S11917
INSTALLATION AND SAFETY INSTRUCTIONS
IMPORTANT: Read before installing fixture. Retain for future reference.
WARNING:
• DANGER: Risk of shock-disconnect power before
installation.
• WARNING: Risk of fire or electric shock. LED Retrofit
Kit installation requires knowledge of luminaire electrical
systems. If not qualified, do not attempt installation. Contact
a qualified electrician.
• WARNING: Product must be installed in accordance with
the national electrical code or your local electrical code.
If you are not familiar with these codes and requirements,
contact a qualified electrician.
• WARNING: Install this kit only in luminaries that have
the construction features and dimensions shown in the
photographs and/or drawing and where the input rating
of the retrofit kit does not exceed the input rating of the
luminaire.
• WARNING: To prevent wiring damage or abrasion, do
not expose wiring to edges of sheet metal or other sharp
objects.
• WARNING: To avoid potential fire or shock hazard, do not
use this retrofit kit in luminaries employing shunted bi-pin
lampholders. NOTE: Shunted lamp holders are found only
in fluorescent luminaries with instant-start ballasts. Instant-
start ballasts can be identified by the words "Instant Start"
or "I.S." marked on the ballast. This designation may be in
the form of a statement pertaining to the ballast itself, or
may be combined with the marking for the lamps with which
the ballast is intended to be used, for example F40T 12/IS,
for more information contact the LED luminaire retrofit kit
manufacturer.
Do not make or alter any open holes in an enclosure of
wiring or electrical components during kit installation.
Installers should not disconnect the existing wire from
lampholder terminals to make new connections at
lampholder terminals. Instead installers should cut existing
lampholder leads away from the lampholder and make
new electrical connections to lampholder lead wires by
employing applicable connectors.
• WARNING: Luminaire wiring and electrical parts may be
damages when installing retrofit kit hardware. Check for
enclosed wiring and components.
The units covered by this report were intended to retrofit surface mount, Type IC or non-IC recessed mount Listed fluorescent luminaires that
use maximum 4 tubular lamps, the minimum lamp compartment dimensions are tabulated below.
Item Number-Description
S11910
11.5T8/LED/48-830/FF/BP 120-277V
S11911
11.5T8/LED/48-835/FF/BP 120-277V
S11912
11.5T8/LED/48-840/FF/BP 120-277V
11.5T8/LED/48-850/FF/BP 120-277V
S11913
18.5T8/LED/48-830/FF/BP 120-277V
S11914
S11915
18.5T8/LED/48-835/FF/BP 120-277V
S11916
18.5T8/LED/48-840/FF/BP 120-277V
S11917
18.5T8/LED/48-850/FF/BP 120-277V
© Copyright 2023 Satco Products, Inc. 6/23 v1.1
• WARNING: Check the existing wiring for damage before
installing upgrade kit. Do not install if existing wires are
damaged.
This retrofit kit is accepted as a component of a luminaire
where the suitability of the combination shall be determined
by authorities having jurisdiction.
THIS RETROFIT KIT INCLUDES, LED TUBE, OPERATING
INSTRUCTIONS, AND FIXTURE LABEL FOR THE DOUBLE
OR SINGLE ENDED APPLICATION.
• "This luminaire has been modified and can no longer operate
the originally intended lamp," shall be marked on the retrofit
luminaire where readily visible by the user during normal
maintenance including lamping.
• Only use the control provided with or specified by these
instructions to control this lamp. This lamp will not operate
properly when connected to a standard (incandescent)
dimmer or dimming control. Only operate with specific
dimmer manufactured by Shanghai Infinex Lighting, type
ECV100W-XXX.
• For indoor use only. Maximum ambient temperature must
not exceed 45ºC (113ºF).
• Suitable for damp locations.
• Not rated for use in vapor tight style fixtures. Do not install
in vapor tight style fixtures.
• Suitable for use in enclosed luminaries.
Not for emergency lighting.
• This device complies with Part 15 of the FCC rules. Operation
is subject to the following two conditions: (1) This device may
not cause harmful interference, and (2) This device must
accept any interference received, including interference that
may cause undesired operation.
Features, applications and installation instructions
continued on pages 2-3.
Minimum Lamp Compartment Dimensions
Volts
(Length x Width x Height)
48 7/16 x 13 3/8 x 1 3/4 inches
120-277V
(1230 x 340 x 45 mm)
1
Lamp
Lamp-to-Lamp
Quantity
Spacing
1 3/16 inches
4
(30mm)
Satco Products, Inc.
Brentwood, NY 11717

Publicité

loading

Sommaire des Matières pour Satco NUVO S11910

  • Page 1 48 7/16 x 13 3/8 x 1 3/4 inches 1 3/16 inches S11913 120-277V 18.5T8/LED/48-830/FF/BP 120-277V (1230 x 340 x 45 mm) (30mm) S11914 S11915 18.5T8/LED/48-835/FF/BP 120-277V S11916 18.5T8/LED/48-840/FF/BP 120-277V S11917 18.5T8/LED/48-850/FF/BP 120-277V Satco Products, Inc. © Copyright 2023 Satco Products, Inc. 6/23 v1.1 Brentwood, NY 11717...
  • Page 2 FEATURES • c-UL-us classified and recognized • Full glass housing: No aging, yellowing, bending APPLICATIONS Widely used in residential buildings, offices, shopping malls, supermarkets, hospitals, assembly lines, warehouses, etc. for energy saving illumination. INSTALLATION: SINGLE-ENDED Remove Existing Fluorescent System • Disconnect power from fixture and remove fluorescent lamp(s). •...
  • Page 3 INSTALLATION: SINGLE-ENDED (Continued) Single Lamp STEP 1: On the Side A lampholder, connect Line (L) and Neutral N(L1) AC wires to the corresponding pins marked (L) and N(L1) on the endcap. If only one lamp is being installed, proceed to STEP 3. Multiple Lamps 120-277V N(L1)
  • Page 4 DERIVACIÓN DE BALASTO T8 LED PREMIUM ESPAÑOL: Modelos: S11910, S11911, S11912, S11913, INSTRUCCIONES DE INSTALACIÓN Y SEGURIDAD S11914, S11915, S11916, S11917 IMPORTANTE: Lea esto antes de instalar el accesorio. Consérvelo para referencia futura. • PELIGRO: Riesgo de descarga, desconecte la alimentación antes de la instalación. •...
  • Page 5 DE DÉRIVATION DE BALLAST À DEL DE QUALITÉ SUPÉRIEURE T8 FRANCAIS: Modèles: S11910, S11911, S11912, S11913, INSTRUCTIONS SUR L’INSTALLATION ET LA SÉCURITÉ S11914, S11915, S11916, S11917 IMPORTANT: Lisez avant d’installer le luminaire. Conservez à titre de référence. • DANGER: Risque de chocs - deconnectez l’alimentation electrique avant l’installation. •...

Ce manuel est également adapté pour:

Nuvo s11911Nuvo s11912Nuvo s11913Nuvo s11914Nuvo s11915Nuvo s11916 ... Afficher tout