5. Setting the switch points
Display:
lit LED = 10% value of the
switching point
flashing LED = 2% value of
the switching point
LED green = last flow value indicated
Press the button and
keep it pressed
(here setting of S1).
1
2
Press for a short time
(= acknowledgement for S1).
*Decrease the switch point: Let the flashing and lit LEDs move to the maximum
setting value. Then the cycle starts again at the minimum setting value.
14
All manuals and user guides at all-guides.com
yellow (YE) = output switched;
red (RD) = output not switched
3
6
The current switch point is
indicated in steps of 2%
(here: 30 + 6 = 36 cm/s),
3
6
after 5s the value is increased*
(incremental by pressing briefly or
scrolling by holding pressed).
Here: 36 - 39 - 42 cm/s
The set value becomes effective;
the unit is reset to the operating
mode.