Giatsu WD2N8B Serie Manuel De L'utilisateur Et D'installation page 107

Publicité

Les langues disponibles
  • FR

Les langues disponibles

Order
Code
number
6.1
ROOM THERMOSTAT
6.2
MODE SET PRIORITY
7.1
IBH FUNCTION
7.2
IBH LOCATE
7.3
dT1_IBH_ON
7.4
t_IBH_DELAY
7.5
T4_IBH_ON
7.6
P_IBH1
7.7
P_IBH2
7.8
AHS FUNCTION
7.9
AHS_PUMPI CONTROL
7.10
dT1_AHS_ON
7.11
t_AHS_DELAY
7.12
T4_AHS_ON
7.13
EnSWITCHPDC
7.14
GAS_COST
7.15
ELE_COST
7.16
MAX_SETHEATER
7.17
MIN_SETHEATER
7.18
MAX_SIGHEATER
7.19
MIN_SIGHEATER
8.1
T1S_H.A_H
PREHEATING FOR
FLOOR-T1S
12.1
t_FIRSTFH
FLOOR DRYING UP
t_DRYUP
t_HIGHPEAK
t_DRYD
12.2
t_DRYPEAK
START TIME
State
Room thermostat type : 0=NON,1=MODESET,2=ONE ZONE
3=DOUBLE ZONE
Select the priority mode in ROOM THERMOSTAT:
0=HEAT,1=COOL
Select the mode that IBH(BACKUP HEATER) can run:
1=HEAT
The installation location of IBH(PIPE LOOP=0)
The temperature difference between T1S and T1 for
starting the backup heater.
The time that the compressor has run before starting the
first step backup heater.
The ambient temperature for starting the backup heater.
Power input of IBH1
Power input of IBH2
Enable or disable the AHS(AUXILIARY HEATING
SOURCE) function:0=NON,1=HEAT
Select the pump operating status when only AHS runs:
0=RUN,1=NOT RUN
The temperature difference between T1S and T1B for
starting the auxiliary heating source.
The time that the compressor has run before starting the
additional heating source
The ambient temperature for starting the additional heating
source
Enable or disable the function that heat pump and auxiliary
heating source switch automatically based on running cost:
0=NON,1=YES
Price of gas
Price of electricity
Maximum setting temperature of additional heating source
Minimum setting temperature of additional heating source
The voltage corresponding to the maximum setting
temperature of additional heating source
The voltage corresponding to the minimum setting
temperature of additional heating source
The target outlet water temperature for space heating
in holiday away mode
The setting temperature of outlet water during first
preheating for floor
Running time for first preheating of the floor
The function of drying up the floor
Temp-up days for floor drying up
Days for floor drying up
Temp-down days for floor drying up
Outlet temperature of floor drying up
The start time of floor drying up
42
Default
Unit
0
/
0
/
1
/
0
/
5
°C
30
min
-5
°C
0
kW
0
kW
0
/
0
/
°C
5
30
min
-5
°C
0
/
0.85
€/m
3
0.20
€/kWh
80
°C
30
°C
10
V
3
V
25
°C
25
°C
72
HOUR
/
/
DAY
8
DAY
5
DAY
5
45
°C
Hour:the
present
time(not on
h/min
the hour +1,
on the hour
+2)
Minute:00