LIGHTING INSTRUCTIONS
1. The Fan will operate automatically when the heater is powered up to an electrical outlet.
2. Allow the heater fan to run for 20 seconds to purge fuel (the first time you use the heater this step is unnecessary).
3. Slowly open the main gas valve at the propane cylinder.
4. Depress and rotate the valve control knob to the "
h
5. After the heater lights, keep the knob depressed for 30 seconds or until the thermocouple warms sufficiently to maintain
3A
combustion.
6. If the heater does not remain lit, repeat the lighting instructions.
7. Turn the knob to the desired heat setting.
SHUTDOWN INSTRUCTIONS
1. Tightly close the gas valve at the propane cylinder.
2. Allow the heater to purge any remaining gas from the hose.
3. Turn the control knob to the "O" position.
4. Disconnect the power cord from the power source.
837-5155.
5. Disconnect the hose assembly from the cylinder and store the cylinder outdoors.
6. Allow the heater to cool before moving or adjusting the heater.
PowerFast
RESTARTING AFTER SHUTDOWN
ose is cut,
1. Securely close the gas valve at the propane cylinder.
2. Disconnect the heater from its power source.
3. Restart following the "Lighting Instructions" procedure.
clockwise
STORAGE AND MAINTENANCE
1. Inspect the heater before and after each use, and at least annually by a qualified
service technician.
2. Inspect the hose assembly for abrasions or wear, or for cuts. If damaged, replace the
FLAME. If
hose prior to operating the heater. Before each use, check the soft "O" ring seal of
the POL fitting. If the "O" ring is cut,scuffed, or otherwise damaged, replace it before
using the heater.
3. Turn off the gas at the LP-gas supply cylinder(s) when the heater is not in use.
4. Store the propane cylinder in accordance with the Standard for the Storage and Handling of Liquefied Petroleum Gases,
NFPA 58 and Natural Gas and Propane Installation Code, CSA B149.1.tore the cylinder outdoors and in accordance with
Chapter 5 of the standard for Storage and Handling of Liquefied Petroleum Gases ANSI/NFPA 58 and CSA B 149.1, Natural
Gas and Propane Installation Code.
SERVICING
At least annually, have the heater inspected and serviced by a qualified service technician. NEVER use a heater that has been
modified from its original condition. For original manufacturer's parts, contact PowerFast Products Group at (423) 837-5155.
All manuals and user guides at all-guides.com
For Troubleshooting Or Technical Support:
Call PowerFast Product Group At: (423) 837 - 5155
Visit Us Online At: www.powerfastproducts.com
WARNING: Never leave the heater unattended while operating.
WARNING: Never leave the heater unattended while operating.
Disconnect the heater from its power source when not in use.
Disconnect the heater from its power source when not in use.