Desoutter E-LIT BOX Manuel Utilisateur page 7

Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 9
English
Timing chart
To make sure that PLC correctly captures OK, NOK, REVERSE and REHIT
signals, each corresponding relay is energized as follows:
Time ON > 1,000 ms
Time OFF > 1,000 ms
Those values are by default and can be modified by using E-LIT PC
software.
Tool not setup for internal batch counter
management:
O: TOOL_READY
TOOL
O: Report
(CYCLE_OK
CYCLE_NOK,
CYCLE_REVERSE
CYCLE_REHIT)
Tool setup for internal batch counter management
I: RESET BATCH
O: TOOL_READY
TOOL
O: Report
(CYCLE_OK
CYCLE_NOK,
CYCLE_REVERSE
CYCLE_REHIT)
O: BATCH_COMPLETE
If a different timing is required to match PLC specifications, please contact us.
01/2014
Time
OFF
Time
ON
7 / 36
6159931280_05
Series: -

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

6159360860

Table des Matières