Télécharger Imprimer la page

Jeulin UT60A Mode D'emploi page 23

Publicité

Les langues disponibles

Les langues disponibles

Measurement and instrumentation
Multimeter model UT60A
Réf :
291 033
ENGLISH
All manuals and user guides at all-guides.com
Remarks:
Continuity Test (400.0Ω) Range Buzzer beeps continuously.
Open circuit voltage approximate 0.45V
Diode Range:
Open circuit voltage approximate 1.48V
Displays approximate forward voltage drop reading 0.5V – 0.8V
400Ω – 40MΩ Range: Open circuit voltage approximate 0.45V
Capacitance
Range Resolution Accuracy Overload Protection
40nF
10pF
± (3%+5)
400n F
100pF
4µF
10nF
± (4%+5)
100µF
100nF
Frequency & Duty Cycle
Range
Resolution Accuracy Overload Protection
10Hz-
N/A
10MHz
0.1%-
99.9%
0.01%
(Duty cycle)
DC Current
Range
Resolution
400µA
0.1µA
4000µA
1µA
40mA
0.01mA
400mA
0.1mA
4A
0.001mA
10A
0.1A
22
600Vp
± (0.1%+3)
600Vp
N/A
Accuracy
± (1%+2)
± (1.2%+3)
± (1.5%+5)
Overload
Protection
0.5A, 250V,
fast type Glass
fuse,
Ø5x20mm
10A, 250V,
fast type Glass
fuse,
Ø 5x20mm

Publicité

loading

Ce manuel est également adapté pour:

291 033